• Journal of cardiology · Dec 2013

    Multicenter Study Comparative Study

    High-sensitivity cardiac troponin T for earlier diagnosis of acute myocardial infarction in patients with initially negative troponin T test--comparison between cardiac markers.

    • Mitsunobu Kitamura, Noritake Hata, Tadateru Takayama, Atsushi Hirayama, Masashi Ogawa, Akira Yamashina, Hisaaki Mera, Hideaki Yoshino, Fumitaka Nakamura, and Yoshihiko Seino.
    • Division of Intensive Care Unit, Nippon Medical School Chiba-Hokusoh Hospital, Chiba, Japan.
    • J Cardiol. 2013 Dec 1;62(6):336-42.

    Background And PurposeAn early diagnosis is essential for therapeutic decision and risk stratification in patients with suspected acute myocardial infarction (AMI). We analyzed and compared the diagnostic value of high-sensitivity troponin T (hs-TnT) and other cardiac markers in patients with an initially negative troponin T test at presentation.Methods And SubjectsThe present study was a prospective, multicenter study including five participating emergency cardiovascular tertiary centers in Japan. From November 2009 through January 2011, patients with suspected AMI at the emergency room with an initial troponin T (c-TnT) test <100 ng/L were enrolled.ResultsA total of 85 patients were prospectively assigned from five participating emergency cardiovascular tertiary centers in Japan. The median time from the onset of chest pain to the T0 sampling was 165 min [IQR 120-180]. The final diagnoses according to the recent universal definition and other standard cut-off values were AMI in 47, unstable angina in 12, and non AMI in 38 patients. The overall ROC-AUC value of hs-TnT, c-TnT, creatine kinase MB, and heart-type fatty acid-binding protein were 0.810, 0.716, 0.782, and 0.880, respectively. The diagnostic sensitivity and negative predictive value of hs-TnT were both 100% for the patients admitted more than 120 min from the onset, however the specificity was limited for the whole time-windows (71%). The absolute value change of the hs-TnT from T0 to T3 sampling 3h later improved the ROC-AUC up to 0.972 and the specificity was 92% at 22 ng/L (ROC-optimized cut-off) and 100% at 105 ng/L (rule-in cut-off).ConclusionsThe hs-TnT displayed 100% sensitivity and negative predictive value for the patients admitted more than 120 min from the onset, however the specificity was limited. The absolute change from T0 to T3 (22 ng/L) improved the total diagnostic performance.Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.