-
Observational Study
Ultrasound localization of central vein catheter tip by contrast-enhanced transthoracic ultrasonography: a comparison study with trans-esophageal echocardiography.
- Francesco Corradi, Fabio Guarracino, Gregorio Santori, Claudia Brusasco, Guido Tavazzi, Gabriele Via, Silvia Mongodi, Francesco Mojoli, Raffaello Umberto Dario Biagini, Alessandro Isirdi, Federico Dazzi, Chiara Robba, Luigi Vetrugno, Francesco Forfori, and UCARE research group.
- Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Pisa, Italy. francesco.corradi@unipi.it.
- Crit Care. 2022 Apr 21; 26 (1): 113.
BackgroundTo assess the usefulness of pre-operative contrast-enhanced transthoracic echocardiography (CE-TTE) and post-operative chest-x-ray (CXR) for evaluating central venous catheter (CVC) tip placements, with trans-esophageal echocardiography (TEE) as gold standard.MethodsA prospective single-center, observational study was performed in 111 patients requiring CVC positioning into the internal jugular vein for elective cardiac surgery. At the end of CVC insertion by landmark technique, a contrast-enhanced TTE was performed by both the apical four-chambers and epigastric bicaval acoustic view to assess catheter tip position; then, a TEE was performed and considered as a reference technique. A postoperative CXR was obtained for all patients.ResultsAs per TEE, 74 (67%) catheter tips were correctly placed and 37 (33%) misplaced. Considering intravascular and intracardiac misplacements together, they were detected in 8 patients by CE-TTE via apical four-chamber view, 36 patients by CE-TTE via epigastric bicaval acoustic view, and 12 patients by CXR. For the detection of catheter tip misplacement, CE-TTE via epigastric bicaval acoustic view was the most accurate method providing 97% sensitivity, 90% specificity, and 92% diagnostic accuracy if compared with either CE-TTE via apical four-chamber view or CXR. Concordance with TEE was 79% (p < 0.001) for CE-TTE via epigastric bicaval acoustic view.ConclusionsThe concordance between CE-TTE via epigastric bicaval acoustic view and TEE suggests the use of the former as a standard technique to ensure the correct positioning of catheter tip after central venous cannulation to optimize the use of hospital resources and minimize radiation exposure.© 2022. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.