• J. Thromb. Thrombolysis · Jun 2008

    Diagnostic value of D-dimer measurement in patients referred to the emergency department with suspected myocardial ischemia.

    • Giuseppe Lippi, Luca Filippozzi, Martina Montagnana, Gian Luca Salvagno, and Gian Cesare Guidi.
    • Sezione di Chimica Clinica, Dipartimento di Scienze Morfologico-Biomediche, Università degli Studi di Verona, Ospedale Policlinico G.B. Rossi, Piazzale Scuro, 10, 37134 Verona, Italy. giuseppe.lippi@univr.it
    • J. Thromb. Thrombolysis. 2008 Jun 1;25(3):247-50.

    BackgroundThe accurate identification of patients with acute myocardial infarction (AMI) remains one of the most difficult challenges facing emergency physicians. The introduction of early and reliable biomarkers of AMI should hence be acknowledged, since they would increase the efficiency of the diagnostic process.MethodsA total of 2,276 consecutive patients referred to the emergency department for clinical symptoms suggestive for AMI underwent cardiac troponin T (cTnT) and D-dimer testing between January and December 2006. Patients sample were eligible for inclusion in this investigation if they had been collected prior to medication or intervention and 12-24 h after the time of patient's arrival to the emergency department, when the diagnostic efficiency of cTnT is the highest. cTnT was assayed on the Elecsys 2010 and test results were stratified according to the decisional threshold corresponding to the lowest TnT concentration associated with a 10% total imprecision in the assay (>0.03 microg/l). Plasma D-dimer was measured employing Vidas DD.ResultsThe results of 741 patient's samples fulfilled the above criteria and were included in the study, 252 (34%) of whom had cTnT values>0.03 microg/l. The D-dimer value distribution (median and 95% C.I.) was significantly different in patients with cTnT values>0.03 microg/l than in those with cTnT values<0.03 microg/l (2,227 microg/l, 431-10,000 microg/l versus 1,039 microg/l, 143-6,338 microg/l; P<0.001). The area under the receiver operating characteristic (ROC) curve, was 0.734 (95% confidence interval: 0.715-0.753; P<0.001). At the 500 microg/l diagnostic threshold estimated by the ROC curve analysis, corresponding to the cut-off for the diagnosis of VTE, sensitivity and specificity of Vidas D-dimer were 95% and 27%, respectively. The positive and negative predictive values were estimated as 92% and 41%, respectively. In linear regression analysis, no significant association (r=0.090; P=0.077) was observed between D-dimer and cTnT in patients with cTnT levels exceeding the decisional threshold of the assay.ConclusionsResults of the present investigation on patients with AMI established by accepted diagnostic criteria (cTnT values above the decisional threshold of the assay associated with suggestive clinical symptoms), testify that D-dimer testing would not add clinically meaningful information to the sole determination of the cardiospecific troponins 12-24 h after patient's admission at the emergency department, when the cumulative data indicate that the diagnostic efficiency of cTnT is the highest.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…