- Tzu-Yao Hung, Wei-Lun Chen, Yung-Cheng Su, Chih-Chieh Wu, Chung-Chun Wang, Hsin-Ling Chen, Shih-Cheng Hu, and Tee Lin.
- Department of Emergency Medicine, Zhong-Xing branch, Taipei City Hospital, Taipei City, Taiwan; Faculty of Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan; School of Medicine, College of Medicine, Fu Jen Catholic University, New Taipei, Taiwan; CrazyatLAB (Critical Airway Training Laboratory), Taipei City, Taiwan.
- Ann Emerg Med. 2022 Jul 1; 80 (1): 22-34.
Study ObjectiveTo evaluate aerosol dispersion and exposure risk during oxygenation therapy among health care personnel.MethodsThis study compared the aerosol dispersion effect produced through continuous positive airway pressure (CPAP), bilevel positive airway pressure (BiPAP), BiPAP with face coverings, a high-flow nasal cannula (HFNC) with face coverings, nasal cannula oxygenation (NCO) at 15 L/min with face coverings, nonrebreather mask (NRM), and ventilator-assisted preoxygenation (VAPOX) during oxygenation therapy at a minute ventilation of 10 L/min and 20 L/min. The length and width of aerosol dispersion were recorded, and aerosol concentrations were then detected at a mannequin's head, trunk, and feet.ResultsThe average length dispersion distance of CPAP was 47.12 cm (SD, 12.56 cm), of BiPAP was 100.13 cm (SD, 6.03 cm), of BiPAP with face coverings was 62.20 cm (SD, 8.46 cm), of HFNC with face coverings was 67.09 cm (SD, 12.74 cm); of NCO with face coverings was 85.55 cm (SD, 7.28 cm); and of NRM was 63.08 cm (SD, 15.33 cm); VAPOX showed no visible dispersion. The aerosol concentrations at the feet under CPAP and at the head under BiPAP were significantly higher than those observed without an oxygen device. Compared with no oxygen device, the aerosol concentration with HFNC was higher at the mannequin's head, trunk, and feet; whereas it was lower with VAPOX and NRM. Moreover, when translated to the number of virus particles required to infect medical personnel (Nf), VAPOX took more time to achieve Nf than other devices.ConclusionStrong flow from the oxygenation devices resulted in increased aerosol concentrations. CPAP at the feet side, BiPAP at the head side, HFNC, and NCO with face coverings significantly increase aerosol exposure and should be used with caution. Aerosol concentrations at all positions were lower with NRM and VAPOX.Copyright © 2022 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.