• Respiration · Jan 2012

    Comparative Study

    Accuracy and precision of desktop spirometers in general practices.

    • Tjard R J Schermer, Eddy H A Verweij, Riet Cretier, Annelies Pellegrino, Alan J Crockett, and Patrick J P Poels.
    • COPD and Asthma Research and Development Unit, Department of Primary and Community Care, Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands.
    • Respiration. 2012 Jan 1;83(4):344-52.

    BackgroundSpirometry has become an essential tool for general practices to diagnose and monitor chronic airways diseases, but very little is known about the performance of the spirometry equipment that is being used in general practice settings. The use of invalid spirometry equipment may have consequences on disease diagnosis and management of patients.ObjectivesTo establish the accuracy and precision of desktop spirometers that are routinely used in general practices.MethodsWe evaluated a random sample of 50 spirometers from Dutch general practices by testing them on a certified waveform generator using 8 standard American Thoracic Society waveforms to determine accuracy and precision. Details about the brand and type of spirometers, year of purchase, frequency of use, cleaning and calibration were inquired with a study-specific questionnaire.Results39 devices (80%) were turbine spirometers, 8 (16%) were pneumotachographs, and 1 (2%) was a volume displacement spirometer. Mean age of the spirometers was 4.3 (SD 3.7) years. Average deviation from the waveform generator reference values (accuracy) was 25 ml (95% confidence interval 12-39 ml) for FEV(1) and 27 ml (10-45 ml) for FVC, but some devices showed substantial deviations. FEV(1) deviations were larger for pneumotachographs than for turbine spirometers (p < 0.0031), but FVC deviations did not differ between the two types of spirometers. In the subset of turbine spirometers, no association between age and device performance was observed.ConclusionsOn average, desktop spirometers in general practices slightly overestimated FEV(1) and FVC values, but some devices showed substantial deviations. General practices should pay more attention to the calibration of their spirometer.Copyright © 2012 S. Karger AG, Basel.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…