• Minerva anestesiologica · May 2022

    Observational Study

    Carotid vs. aortic velocity time integral and peak velocity to predict fluid responsiveness in mechanically ventilated patients. A comparative study.

    • Rocco Pace, Sergio Lassola, Sara Miori, Gianmaria Cammarota, Federico Barbariol, and Luigi Vetrugno.
    • Intensive Care Unit, Department of Anesthesia and Intensive Care, Santa Chiara Hospital, Trento, Italy - rocco.pace@apss.tn.it.
    • Minerva Anestesiol. 2022 May 1; 88 (5): 352-360.

    BackgroundThe carotid artery velocity-time integral (CVTI) and the carotid Doppler peak velocity (cDPV), as well as measures of their variation induced by the respiratory cycle, have been proposed as fast and easy to obtain ultrasound measures for assessing fluid responsiveness in intensive care unit patients. To investigate this possibility, we conducted a prospective observational study in hemodynamically unstable patients under mechanical ventilation.MethodsFrom May 1 to December 31, 2019, we conducted a prospective observational study involving 50 hemodynamically unstable patients under mechanical ventilation. We obtained a total of 800 Doppler ultrasound measurements from the left common carotid artery and at the level of the aortic annulus in the apical five-chamber view. The two measurements were performed before and after a 7 mL/kg fluid challenge and within the first hour of the onset of hemodynamic instability. The maximum Doppler peak velocity, the minimum Doppler peak velocity, and the maximum and minimum VTI at both the aortic and carotid level were acquired.ResultsTwenty-eight (56%) patients showed a ≥15% increase in AoVTI after the fluid challenge, and were therefore identified as "fluid responders". All Doppler measurements were always significantly greater (P<0.0001) in fluid responders in relation to both carotid and aortic parameters. Good agreement between the above-mentioned measurements was found: Cohen's kappa coefficient between the carotid and aortic ΔDPV was 0.76 (95% CI 0.58-0.94); and between the Carotid and Aortic ΔVTI it was 0.84 (95% CI 0.68-0.99).ConclusionsCDPV was found to predict fluid responsiveness in unstable mechanically ventilated patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.