-
J Clin Monit Comput · Jun 2007
Importance and interpretation of fast-response airway hygrometry during ventilation of anesthetized patients.
- Abraham Rosenbaum and Peter H Breen.
- Department of Anesthesiology, UCI Medical Center, University of California, Irvine, Building 53, Room 227, 101 The City Drive South, Orange, CA 92868, USA.
- J Clin Monit Comput. 2007 Jun 1; 21 (3): 137-46.
BackgroundMeasurement of oxygen uptake (Vo2) should help detect non-steady state critical events and metabolic derangement during anesthesia. Vo2 requires measurement of respiratory relative humidity (RH) and temperature (T). We have developed a fast response T and humidity sensor (HS), which uses tiny wet and dry thermometers to determine RH by psychrometry, where low RH causes evaporation to decrease wet T below dry T. In laboratory bench studies, we determined that >/=5 l/min gas flow through the HS is required for valid psychrometry function. This study demonstrates that monitoring of flow through the HS enhances the accuracy of RH measurement and interpretation.MethodsPhase One: Laboratory bench validation; We designed a special bench setup for the validation of metabolic gas exchange compared to precise ethanol combustion. Phase 2: Clinical study; During mechanical ventilation of 6 anesthetized surgical patients, airway flow was used to successfully select valid wet T and dry T during inspiration and expiration, from which respective RH's were calculated using principles of psychrometry.ResultsThe average (+/-SD) percent error for airway Vco2 (compared to the stoichiometric value) was -1.84 +/- 2.69% (Table 2). The average (+/-SD) percent error for airway Vo2 was 0.91 +/- 3.10%. Average RQ was 0.649 +/- 0.017. For all patients, average inspired RH was 36.1 +/- 11.8% (range of 17-52%), which differed significantly from expiration (103 +/- 9%). Among the 6-8 consecutive breaths for each patient, average standard deviations of expired RH were only 0.6%.ConclusionWe conclude that airway flow monitoring enhances the interpretation and accuracy of the fast-response HS measurements during inspiration and expiration, allowing for the determination of Vo2 in patients during anesthesia.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.