-
- Christopher F Chesley, Meghan B Lane-Fall, Venkat Panchanadam, Michael O Harhay, Arshad A Wani, Mark E Mikkelsen, and Barry D Fuchs.
- Pulmonary, Allergy, and Critical Care Division, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania; Palliative and Advanced Illness Research Center, Department of Medicine, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania; and Leonard Davis Institute of Health Economics, University of Pennsylvania, Philadelphia, Pennsylvania. christopher.chesley@pennmedicine.upenn.edu.
- Respir Care. 2022 Dec 1; 67 (12): 149915071499-1507.
BackgroundPulse oximetry is the mainstay of patient oxygen monitoring. Measurement error from pulse oximetry is more common for those with darker skin pigmentation, yet this topic remains understudied, and evidence-based clinical mitigation strategies do not currently exist. Our objectives were to measure the rate of occult hypoxemia, defined as arterial oxygen saturation (SaO2 ) < 88% when pulse oximeter oxygen saturation was between 92-96%, in a racially diverse critically ill population; to analyze degree, direction, and consistency of measurement error; and to develop a mitigation strategy that minimizes occult hypoxemia in advance of technological advancements.MethodsWe performed a multi-center retrospective cohort study of critically ill subjects.ResultsAmong 105,467 paired observations from 7,693 subjects, we found occult hypoxemia was more common among minority subjects. The frequency of occult hypoxemia was 7.9% versus 2.9% between Black and white subjects, respectively, (P < .001). Pulse oximeter measurement errors were inconsistent throughout a patient encounter, with 67% of encounters having a range of intra-subject measurement errors > 4 percentage points. In 75% of encounters, the intra-subject errors were bidirectional. SaO2 < 88% was less common at higher pulse oximeter oxygenation ranges (4.1% and 1.8% of observations among Black and white subjects at a pulse oximeter threshold of 94-98%). Although occult hypoxemia was further reduced at oxygenation saturation range 95-100%, the frequency of hyperoxemia (partial pressure of arterial oxygen > 110 mm Hg) became more common, occurring in 42.3% of Black and 46.0% of white observations.ConclusionsMeasurement error in pulse oximetry is common for all racial groups, but occult hypoxemia occurred most commonly in Black subjects. The highly variable magnitude and direction of measurement error preclude an individualized mitigation approach. In advance of technological advancements, we recommend targeting a pulse oximetry saturation goal of 94-98% for all patients.Copyright © 2022 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.