- Aiman Suleiman, Eduardo Costa, Peter Santer, Tim M Tartler, Luca J Wachtendorf, Bijan Teja, Guanqing Chen, Elias Baedorf-Kassis, Alexander Nagrebetsky, Vidal MeloMarcos FMFDepartment of Anesthesiology, Columbia University Irving Medical Center, New York, NY, USA. Electronic address: mv2869@cumc.columbia.edu., Matthias Eikermann, and Maximilian S Schaefer.
- Department of Anaesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Centre, Boston, MA, USA; Center for Anaesthesia Research Excellence (CARE), Beth Israel Deaconess Medical Centre, Boston, MA, USA; Department of Anaesthesia and Intensive Care, Faculty of Medicine, University of Jordan, Amman, Jordan.
- Br J Anaesth. 2022 Aug 1; 129 (2): 263272263-272.
BackgroundThe impact of high vs low intraoperative tidal volumes on postoperative respiratory complications remains unclear. We hypothesised that the effect of intraoperative tidal volume on postoperative respiratory complications is dependent on respiratory system elastance.MethodsWe retrospectively recorded tidal volume (Vt; ml kg-1 ideal body weight [IBW]) in patients undergoing elective, non-cardiothoracic surgery from hospital registry data. The primary outcome was respiratory failure (requiring reintubation within 7 days of surgery, desaturation after extubation, or both). The primary exposure was defined as the interaction between Vt and standardised respiratory system elastance (driving pressure divided by Vt; cm H2O/[ml kg-1]). Multivariable logistic regression models, with and without interaction terms (which categorised Vt as low [Vt ≤8 ml kg-1] or high [Vt >8 ml kg-1]), were adjusted for potential confounders. Additional analyses included path mediation analysis and fractional polynomial modelling.ResultsOverall, 10 821/197 474 (5.5%) patients sustained postoperative respiratory complications. Higher Vt was associated with greater risk of postoperative respiratory complications (adjusted odds ratio=1.42 per ml kg-1; 95% confidence interval [CI], 1.35-1.50]; P<0.001). This association was modified by respiratory system elastance (P<0.001); in patients with low compliance (<42.4 ml cm H2O-1), higher Vt was associated with greater risk of postoperative respiratory complications (adjusted risk difference=0.3% [95% CI, 0.0-0.5] at 41.2 ml cm H2O-1 compliance, compared with 5.8% [95% CI, 3.8-7.8] at 14 ml cm H2O-1 compliance). This association was absent when compliance exceeded 41.2 ml cm H2O-1. Adverse effects associated with high Vt were entirely mediated by driving pressures (P<0.001).ConclusionsThe association of harm with higher tidal volumes during intraoperative mechanical ventilation is modified by respiratory system elastance. These data suggest that respiratory elastance should inform the design of perioperative trials testing intraoperative ventilatory strategies.Copyright © 2022 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.