• Injury · Jul 2022

    Low interobserver and intraobserver reliability using the Matta radiographic system for intraoperative assessment of reduction following acetabular ORIF.

    • Brendan R Southam, Amanda J Schroeder, Nihar S Shah, Frank R Avilucea, Ryan P Finnan, and Michael T Archdeacon.
    • Department of Orthopaedics and Sports Medicine, University of Cincinnati Medical Center, Cincinnati, OH, USA. Electronic address: Brendan.southam@uc.edu.
    • Injury. 2022 Jul 1; 53 (7): 2595-2599.

    IntroductionThe system described by Matta for rating acetabular fracture quality of reduction following ORIF has been used extensively throughout the literature. However, the reliability of this system remains to be validated. We sought to determine the interobserver and intraobserver reliability of this system when used by fellowship-trained pelvic and acetabular surgeons to evaluate intraoperative fluoroscopy.MethodsThis is a retrospective evaluation of a prospectively collected acetabular fracture database at an academic level I trauma center. The quality of reduction of all acetabular fractures treated with open reduction internal fixation (ORIF) between May 2013 and December 2015 was assessed using three standard intraoperative fluoroscopic views (anteroposterior and two 45˚ oblique Judets). Displacement of ≤1 mm was considered to be an anatomic reduction, 2-3 mm imperfect, and >3 mm poor according to the system described by Matta. A total of 107 acetabular fractures treated with ORIF with complete intraoperative fluoroscopic images during that time period were available for review. Acetabular fracture reductions were reviewed by the operative surgeon at the time of surgery and subsequently reviewed by two fellowship-trained pelvic and acetabular surgeons. All reduction assessments were performed in a blinded fashion. The primary outcome measure was interobserver reliability for assessing reduction quality. This was evaluated using a weighted kappa (κw) statistic between each evaluator and the operative surgeon and a generalized kappa (κg) for all 3 surgeons. After a 6-week "washout interval," the surgeons reviewed the images again and intraobserver agreement was calculated using a weighted kappa statistic.ResultsInterobserver reliability based on the initial assessment was low (κg = 0.09); however, did slightly improve with the second assessment to fair (κg = 0.24). Intraobserver reliability ranged from slight (κw = 0.20) to moderate (κw = 0.53) among the surgeons.DiscussionLow interobserver and intraobserver reliability was found when quality of reduction was assessed with intraoperative fluoroscopic images by the operative and two other pelvic and acetabular surgeons using the Matta system. Given the importance of an anatomic reduction on functional and radiographic outcomes, an accurate and reliable system for assessing intraoperative quality of reduction is essential.Copyright © 2022. Published by Elsevier Ltd.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.