-
Case Reports
Change in Lung Fluid Volume during Exercise in Patients with Exercise-Induced Mitral Regurgitation.
- Teruhiko Imamura, Masakazu Hori, Shuhei Tanaka, Nikhil Narang, and Koichiro Kinugawa.
- Second Department of Internal Medicine, University of Toyama, Toyama 930-0194, Japan.
- Medicina (Kaunas). 2022 May 28; 58 (6).
AbstractExercise-induced mitral regurgitation (MR) can be diagnosed during stress echocardiography testing. Remote dielectric sensing (ReDSTM) is a noninvasive electromagnetic-based modality to measure lung fluid levels. The change in lung fluid levels in patients with MR during stress echocardiography remains unknown. Patients with symptomatic MR at baseline and suspected worsening exercise-induced MR underwent stress echocardiography. ReDS values were measured before and after the tests. A total of four patients (ages ranging between 74 and 84 years old, three women) underwent stress echocardiography testing using a bicycle ergometer. In patient A, MR effective regurgitant orifice area (EROA) remained unchanged and ReDS values decreased. EROA increased significantly with a small incremental change in ReDS values in patient B and patient C, who underwent valve repair with MitraClip later. Patient D had a mild increase in MR EROA but a considerable increase in ReDS values (from 22% to 32%), and eventually received valve repair with MitraClip. The ReDS system may be a complementary tool to conventional stress echocardiography in the evaluation of clinically significant MR and considering mitral valve intervention.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.