- Holger Gässler, Lara Kurka, Stefan Rauch, Stephan Seewald, Martin Kulla, and Matthias Fischer.
- German Armed Forces Hospital Ulm, Department of Anaesthesiology, Intensive Care Medicine, Emergency Medicine and Pain Therapy, Ulm, Germany. Electronic address: holger.gaessler@uni-ulm.de.
- Resuscitation. 2022 Oct 1; 179: 183-188.
AimAccording to the current resuscitation guidelines, the use of mechanical chest compression devices could be considered under special circumstances like transport with ongoing resuscitation or long-term resuscitation. The aim of this study was to investigate whether survival is improved using mechanical devices under such circumstances.MethodsOut-of-hospital cardiac arrests from all high-quality data centres of the German Resuscitation Registry from 2007 to 2020 were investigated. The use of mechanical devices was compared separately for transport with ongoing resuscitation, prolonged resuscitation (>45 min), and resuscitation with fibrinolytic agents applied. Baseline characteristics, 30-day survival/discharged alive, and neurological function at discharge were analysed descriptively; and 30-day survival/discharged alive was additionally analysed using multivariate logistic regression.ResultsOverall, patients who were treated with a mechanical device tended to be younger and were significantly more likely to have a witnessed cardiac arrest and a shockable initial rhythm. During the study period, 4,851 patients were transported to hospital with ongoing resuscitation (devices used in 44.2%). The 30-day survival was equal (odds ratio, OR: 1.13, 95%-CI: 0.79-1.60). In 3,920 cases, a resuscitation duration > 45 min was documented (9.5% with device). When a device was used, 30-day survival was significantly increased (OR 2.33, 95%-CI: 1.30-4.15). Fibrinolytic agents were used in 2,106 patients (22.2% with device). Here, 30-day survival was significantly worse with a device (OR: 0.52, 95%-CI: 0.30-0.91).ConclusionMechanical devices are not associated with better survival when used during transport, but rescuer safety could still be an important argument for their use. Devices are associated with better survival in prolonged resuscitation, but worse survival when a fibrinolytic was used.Copyright © 2022 Elsevier B.V. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.