• Intensive care medicine · Dec 2000

    Comparative Study

    Accuracy of totally implanted ports, tunnelled, single- and multiple-lumen central venous catheters for measurement of central venous pressure.

    • F Blot, A Laplanche, B Raynard, N Germann, S Antoun, and G Nitenberg.
    • Service de Réanimation Polyvalente, Institut Gustave Roussy, Villejuif, France. blot@igr.fr
    • Intensive Care Med. 2000 Dec 1;26(12):1837-42.

    ObjectiveTo verify the accuracy of totally implanted ports, tunnelled central venous catheters (CVC), widely used in cancer patients, and multi-lumen catheters, used in intensive care units (ICUs), in measuring central venous pressure (CVP), using right atrial pressure (RAP) measured in a Swan-Ganz catheter as the reference standard.DesignA prospective study, over a 10-month period.SettingA medical-surgical ICU in a comprehensive cancer centre.Patients And ParticipantsPatients who had both (1) a Swan-Ganz catheter and (2) either a tunnelled catheter, a single or a multi-lumen catheter, or a totally implanted port.InterventionsRAP and CVP were measured simultaneously in each patient.Measurements And ResultsFifty-six pairs of RAP-CVP measurements were performed in 35 patients: 6 tunnelled catheters, 6 non-tunnelled single-lumen catheters, 26 multiple-lumen catheters and 18 totally implanted ports were studied. RAP measured in the Swan-Ganz catheter and CVP measured in the CVC were strongly correlated (r = 0.94, p < 0.01), whatever the type of catheter studied. The mean difference between RAP and CVP was -0.39 +/- 1.73 (SD) mmHg. In 51 cases (91%), the difference was within the limits of agreement (-3.78 to 3.00 mmHg, Bland and Altman method). For the five cases with a difference of 4 mmHg (three totally implanted ports, one double- and one triple-lumen catheter), CVP was greater than RAP.ConclusionsCVP can be accurately measured in totally implanted ports, tunnelled or non-tunnelled single-lumen and multiple-lumen catheters. When the difference exceeds the limit of agreement, the discrepancy between the two measurements has limited significance in most cases.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.