• Critical care medicine · Nov 2022

    Lung Ultrasound Signs to Diagnose and Discriminate Interstitial Syndromes in ICU Patients: A Diagnostic Accuracy Study in Two Cohorts.

    • Micah L A Heldeweg, Marry R Smit, Shelley R Kramer-Elliott, Mark E Haaksma, Jasper M Smit, Laura A Hagens, Nanon F L Heijnen, Annemijn H Jonkman, Frederique Paulus, Marcus J Schultz, GirbesArmand R JARJDepartment of Intensive Care Medicine, Amsterdam University Medical Centers, VUmc, Amsterdam, The Netherlands., HeunksLeo M ALMADepartment of Intensive Care Medicine, Amsterdam University Medical Centers, VUmc, Amsterdam, The Netherlands., BosLieuwe D JLDJDepartment of Intensive Care Medicine, Amsterdam University Medical Centers, AMC, Amsterdam, The Netherlands., and Pieter R Tuinman.
    • Department of Intensive Care Medicine, Amsterdam University Medical Centers, VUmc, Amsterdam, The Netherlands.
    • Crit. Care Med. 2022 Nov 1; 50 (11): 160716171607-1617.

    ObjectivesTo determine the diagnostic accuracy of lung ultrasound signs for both the diagnosis of interstitial syndrome and for the discrimination of noncardiogenic interstitial syndrome (NCIS) from cardiogenic pulmonary edema (CPE) in a mixed ICU population.DesignA prospective diagnostic accuracy study with derivation and validation cohorts.SettingThree academic mixed ICUs in the Netherlands.PatientsConsecutive adult ICU patients that received a lung ultrasound examination.InterventionsNone.Measurements And Main ResultThe reference standard was the diagnosis of interstitial syndrome (NCIS or CPE) or noninterstitial syndromes (other pulmonary diagnoses and no pulmonary diagnoses) based on full post-hoc clinical chart review except lung ultrasound. The index test was a lung ultrasound examination performed and scored by a researcher blinded to clinical information. A total of 101 patients were included in the derivation and 122 in validation cohort. In the derivation cohort, patients with interstitial syndrome ( n = 56) were reliably discriminated from other patients based on the presence of a B-pattern (defined as greater than or equal to 3 B-lines in one frame) with an accuracy of 94.7% (sensitivity, 90.9%; specificity, 91.1%). For discrimination of NCIS ( n = 29) from CPE ( n = 27), the presence of bilateral pleural line abnormalities (at least two: fragmented, thickened or irregular) had the highest diagnostic accuracy (94.6%; sensitivity, 89.3%; specificity, 100%). A diagnostic algorithm (Bedside Lung Ultrasound for Interstitial Syndrome Hierarchy protocol) using B-pattern and bilateral pleural abnormalities had an accuracy of 0.86 (95% CI, 0.77-0.95) for diagnosis and discrimination of interstitial syndromes. In the validation cohort, which included 122 patients with interstitial syndrome, bilateral pleural line abnormalities discriminated NCIS ( n = 98) from CPE ( n = 24) with a sensitivity of 31% (95% CI, 21-40%) and a specificity of 100% (95% CI, 86-100%).ConclusionsLung ultrasound can diagnose and discriminate interstitial syndromes in ICU patients with moderate-to-good accuracy. Pleural line abnormalities are highly specific for NCIS, but sensitivity is limited.Copyright © 2022 by the Society of Critical Care Medicine and Wolters Kluwer Health, Inc. All Rights Reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…