-
- George Deng, Ashley Smith, and Robert Burnham.
- Vivo Cura Health, Calgary, Alberta, Canada; Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Alberta, Canada.
- Pain Physician. 2022 Aug 1; 25 (5): 391-399.
BackgroundRadiofrequency ablation (RFA) for the lumbar facet joints has demonstrated efficacy in the management of chronic low back pain. The traditional technique uses a conventional monopolar (CM) cannula placed parallel to the putative nerve to produce a thermal lesion resulting in pain relief of the facet joints. A new multi-tined (MT) cannula has come onto the market that allows targeting the putative nerve using a perpendicular to the nerve approach.ObjectivesThis study describes the technique using the MT cannula and compares its efficacy and procedural characteristics to the CM cannula.Study DesignThis is a pre-post crossover observational study.MethodsFifty-one patients were recruited between June 2015 and March 2020. Each patient underwent 2 fluoroscopic guided lumbosacral RFA procedures on 2 separate occasions at the same facet joints, using the CM and MT cannula consecutively. The primary outcome measure was change in pain on the 11-point numeric rating scale (NRS). Secondary outcome measures included change in Pain Disability Quality of Life Questionnaire (PDQQ) score, duration and magnitude of pain relief, local anesthetic use, adverse events, procedural and fluoroscopy exposure time, and radiation dose.ResultsThere were no statistically significant difference between CM versus MT canula in terms of absolute (4.0 versus 4.3) and relative (52% versus 57%) change in NRS (P = 0.99) and PDQQ (22 versus 22, P = 0.61) at 3 months, or overall pain magnitude (71% versus 72%, P = 0.96) and duration of relief (8.7 months versus 8.4 months, P = 0.68). The procedures using the MT cannula were completed faster (37.6 minutes versus 31.1 minutes, P < 0.001) and required less local anesthetic (15.8 mL versus 11.0 mL, P < 0.001) and radiation dose (41.5 mGy versus 30.2 mGy, P = 0.05). No adverse events were observed with either cannula.LimitationsThis was an observational study at a single center with the proceduralist not blinded to the intervention.ConclusionThis study demonstrated that the outcomes in terms of pain, disability, quality of life, adverse events, and fluoroscopy exposure time were equivalent between the 2 cannulae. However, RFA using the MT cannula was faster to perform and involved less local anesthetic and radiation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.