J Clin Monit Comput · Apr 2023
Observational StudyComparison of mainstream end tidal carbon dioxide on Y-piece side versus patient side of heat and moisture exchanger filters in critically ill adult patients: a prospective observational study.
- Satoshi Tamashiro, Izumi Nakayama, Koichiro Gibo, and Junichi Izawa.
- Department of Clinical Engineering, Okinawa Prefectural Nanbu Medical Center and Children's Medical Center, Haebaru, Okinawa, Japan.
- J Clin Monit Comput. 2023 Apr 1; 37 (2): 399407399-407.
AbstractThe purpose of the study was to investigate the accuracy of mainstream EtCO2 measurements on the Y-piece (filtered) side of the heat and moisture exchanger filter (HMEF) in adult critically ill patients, compared to that on the patient (unfiltered) side of HMEF. We conducted a prospective observational method comparison study between July 2019 and December 2019. Critically ill adult patients receiving mechanical ventilation with HMEF were included. We performed a noninferiority comparison of the accuracy of EtCO2 measurements on the two sides of HMEF. The accuracy was measured by the absolute difference between PaCO2 and EtCO2. We set the non-inferiority margin at + 1 mmHg in accuracy difference between the two sides of HMEF. We also assessed the agreement between PaCO2 and EtCO2 using Bland-Altman analysis. Among thirty-seven patients, the accuracy difference was - 0.14 mmHg (two-sided 90% CI - 0.58 to 0.29), and the upper limit of the CI did not exceed the predefined margin of + 1 mmHg, establishing non-inferiority of EtCO2 on the Y-piece side of HMEF (P for non-inferiority < 0.001). In the Bland-Altman analyses, 95% limits of agreement between PaCO2 and EtCO2 were similar on both sides of HMEF (Y-piece side, - 8.67 to + 10.65 mmHg; patient side, - 8.93 to + 10.67 mmHg). The accuracy of mainstream EtCO2 measurements on the Y-piece side of HMEF was noninferior to that on the patient side in critically ill adults. Mechanically ventilated adult patients could be accurately monitored with mainstream EtCO2 on the Y-piece side of the HMEF unless their tidal volume was extremely low.© 2022. The Author(s), under exclusive licence to Springer Nature B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.