Diabetes Technol. Ther. · Mar 2009
In silico evaluation platform for artificial pancreatic beta-cell development--a dynamic simulator for closed-loop control with hardware-in-the-loop.
- Eyal Dassau, Cesar C Palerm, Howard Zisser, Bruce A Buckingham, Lois Jovanovic, and Francis J Doyle.
- Department of Chemical Engineering, Univ. of California at Santa Barbara, California; Biomolecular Science & Engineering Program, Univ. of California at Santa Barbara, California; Sansum Diabetes Research Institute, Santa Barbara, California, USA.
- Diabetes Technol. Ther. 2009 Mar 1;11(3):187-94.
BackgroundA critical step in algorithm development for an artificial beta-cell is extensive in silico testing. Computer simulations usually involve only the controller software, leaving untested the hardware elements, including the critical communication interface between the controller and the glucose sensor and insulin pump.MethodsAn in silico simulation platform has been developed that uses all of the components of the clinical system. At the core is a comprehensive in silico population model that covers the variability of principal metabolic parameters observed in vivo, to replace the human subject, with the ability to use historical clinical data. A continuous glucose monitor, in this case either the Abbott Diabetes Care (Alameda, CA) FreeStyle Navigator or the DexCom (San Diego, CA) STS7, is supplied with a glucose signal provided by the simulator. The Insulet (Bedford, MA) OmniPod insulin pump is also interfaced with the simulator to provide insulin delivery data. These hardware elements are an integral part of the system under testing, which also includes the algorithm components.ResultsThe system is unique in that it uses the same hardware components for simulations as are required in clinical trials, allowing for full-system level verification and validation. With a detailed mathematical model, a suite of patients can be simulated to reflect various conditions. Because all hardware is used, their related limitations are automatically included.ConclusionsA complete artificial beta-cell evaluation platform was realized with the flexibility to interface various algorithms and patient models, allowing for the systematic analysis of monitoring and control algorithms. The system facilitates a variety of tests and challenges to the software and the component devices, streamlining preclinical validation trials.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.