• Can J Anaesth · Nov 2022

    Accuracy and trending ability of finger plethysmographic cardiac output monitoring in late pregnancy.

    • Paul Bonnin, Benjamin Constans, Alain Duhamel, Maéva Kyheng, Anne-Sophie Ducloy-Bouthors, Max Gonzalez Estevez, Benoit Tavernier, and Alexandre Gaudet.
    • CHU Lille, Pôle d'Anesthésie-Réanimation, Lille, France.
    • Can J Anaesth. 2022 Nov 1; 69 (11): 134013481340-1348.

    PurposeIndividuals in late pregnancy are at risk of significant hemodynamic variations, especially during Cesarean delivery. Although non-invasive monitoring might enable the early detection of variations in cardiac output (CO), clinical validation is lacking.MethodsIn a prospective, single-center study, we measured CO simultaneously with finger plethysmography and transthoracic echocardiography in 100 third-trimester pregnant individuals in the supine and left lateral decubitus (LLD) positions.ResultsA Bland-Altman analysis revealed a mean (standard deviation) bias of 1.36 (1.04) L·min-1 in the supine position (95% limits of agreement, -0.68 to 3.4 L·min-1; percent error, 26.6%), indicating overestimation by finger plethysmography. The intra-class correlation coefficient was 0.43 (95% confidence interval [CI], 0.33 to 0.51). Regarding the changes in CO induced by the supine-to-LLD transition, the concordance rate in a four-quadrant plot was 98.3% (95% CI, 91.1 to 99.9%).ConclusionOur study showed a poor reliability of finger plethysmography for static measurement of CO. Nevertheless, finger plethysmography had a reasonably high concordance rate for the detection of CO changes secondary to positional changes in late-pregnant individuals. STUDY REGISTRATION DATE: www.Clinicaltrialsgov (NCT03735043); registered 8 November 2018.© 2022. Canadian Anesthesiologists' Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.