• J. Thorac. Cardiovasc. Surg. · May 2023

    Robotic-assisted cryothermic Cox maze for persistent atrial fibrillation: Longitudinal follow-up.

    • Ayman Almousa, J Hunter Mehaffey, Lawrence M Wei, Amy Simsa, HayangaJ W AworiJWADepartment of Cardiovascular and Thoracic Surgery, West Virginia University, Morgantown, Wva., Chris Cook, J Scott Rankin, and Vinay Badhwar.
    • Department of Cardiovascular and Thoracic Surgery, West Virginia University, Morgantown, Wva.
    • J. Thorac. Cardiovasc. Surg. 2023 May 1; 165 (5): 18281836.e11828-1836.e1.

    ObjectivesSurgical ablation of atrial fibrillation (AF) is recommended as a stand-alone therapy for patients refractory to medical or catheter-based treatment, or as a concomitant therapy when associated with structural disease. We report a single-therapy robotic approach to the Cox maze with longitudinal follow-up.MethodsConsecutive patients who underwent robotic biatrial cryothermic Cox maze for nonparoxysmal AF between November 2016 and January 2022 were examined at 1, 2, 3, 6, 9, 12, 18, 24, 36, 48, and 60 months. Freedom from atrial tachyarrhythmia was assessed with 24-hour continuous electrocardiogram or pacemaker interrogation in all patients after 6 months. Mean follow-up was 17 ± 14.5 months (range, 1-60 months). Time to event analysis with competing risks was used to determine risk-adjusted associations with late outcomes.ResultsPatients (n = 135) had a median AF duration of 4.0 years (interquartile range, 0.8-7.0), with 29.6% in whom 1 or more catheter ablations had failed. Stand-alone maze was performed in 25.2%, whereas 61.4% underwent concomitant robotic mitral valve surgery, 7.4% tricuspid valve repair, and 4.4% aortic valve replacement. No patients were discharged in AF. There were 3 operative mortalities (2.2%), none in stand-alone patients. One patient required catheter ablation at 8 months postoperatively, and one had a nonembolic stroke at 18 months. There were 9 late deaths. Freedom from atrial tachyarrhythmia and antiarrhythmic drugs at 9, 12, 18, 24, 36, and 48 months was 97.0%, 96.7%, 98.1%, 97.1%, and 100%, respectively. Lower ejection fraction and need for concomitant mitral valve replacement and/or aortic valve replacement were independently associated with worse survival.ConclusionsFor persistent AF, robotic biatrial cryothermic Cox maze offered greater than 90% 1-year longitudinal freedom from stroke, oral anticoagulation, repeat ablation, and recurrent AF without the need for antiarrhythmic drugs.Copyright © 2022 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…