- Joan-Daniel Martí, Roberto Martínez-Alejos, Xabier Pilar-Diaz, Hua Yang, Francesco Pagliara, Denise Battaglini, Andrea Meli, Milan Yang, Joaquim Bobi, Monsterrat Rigol, Oystein Tronstad, Marcia Souza Volpe, Marcelo Britto Passos Amato, BassiGianluigi LiGLInstitut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain; Physiotherapy Department, The Prince Charles Hospital, Brisbane, Australia; University of Queensland, Brisbane, Australia; Queensland University of Technology, , and Antoni Torres.
- Cardiac Surgery Critical Care Unit, Institut Clinic Cardiovascular, Hospital Clínic, Barcelona, Spain; and Institut d'Investigacions Biomèdiques August Pi i Sunyer, Barcelona, Spain.
- Respir Care. 2022 Dec 1; 67 (12): 150815161508-1516.
BackgroundMechanical insufflation-exsufflation (MI-E) has been proposed as a potential strategy to generate high expiratory flows and simulate cough in the critically ill. However, efficacy and safety of MI-E during invasive mechanical ventilation are still to be fully elucidated. This study in intubated and mechanically ventilated pigs aimed to evaluate the effects of 8 combinations of insufflation-exsufflation pressures during MI-E on mucus displacement, respiratory flows, as well as respiratory mechanics and hemodynamics.MethodsSix healthy Landrace-Large White female pigs were orotracheally intubated, anesthetized, and invasively ventilated for up to 72 h. Eight combinations of insufflation-exsufflation pressures (+40/-40, +40/-50, +40/-60, +40/-70, +50/-40, +50/-50, +50/-60, +50/-70 cm H2O) were applied in a randomized order. The MI-E device was set to automatic mode, medium inspiratory flow, and an inspiratory-expiratory time 3 and 2 s, respectively, with a 1-s pause between cycles. We performed 4 series of 5 insufflation-exsufflation cycles for each combination of pressures. Velocity and direction of movement of a mucus simulant containing radio-opaque markers were assessed through sequential lateral fluoroscopic images of the trachea. We also evaluated respiratory flows, respiratory mechanics, and hemodynamics before, during, and after each combination of pressures.ResultsIn 3 of the animals, experiments were conducted twice; and for the remaining 3, they were conducted once. In comparison to baseline mucus movement (2.85 ± 2.06 mm/min), all insufflation-exsufflation pressure combinations significantly increased mucus velocity (P = .01). Particularly, +40/-70 cm H2O was the most effective combination, increasing mucus movement velocity by up to 4.8-fold (P < .001). Insufflation pressure of +50 cm H2O resulted in higher peak inspiratory flows (P = .004) and inspiratory transpulmonary pressure (P < .001) than +40 cm H2O.ConclusionsMI-E appeared to be an efficient strategy to improve mucus displacement during invasive ventilation, particularly when set at +40/-70 cm H2O. No safety concerns were identified although a transient significant increase of transpulmonary pressure was observed.Copyright © 2022 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.