J Clin Monit Comput · Apr 2023
Observational StudyAssessing a novel second generation laryngeal mask airway using the 'ADEPT' approach: results from the LMA® Protector™ observational study.
- A Ní Eochagáin, V Athanassoglou, A Cumberworth, O Morris, S Corbett, H Jefferson, E P O'Sullivan, and J J Pandit.
- Consultant Anaesthetist St. James's Hospital, Dublin, Ireland.
- J Clin Monit Comput. 2023 Apr 1; 37 (2): 517524517-524.
AbstractTo address the problem of lack of clinical evidence for airway devices introduced to the market, the Difficult Airway Society (UK) developed an approach (termed ADEPT; Airway Device Evaluation Project Team) to standardise the model for device evaluation. Under this framework we assessed the LMA Protector, a second generation laryngeal mask airway. A total of 111 sequential adult patients were recruited and the LMA Protector inserted after induction of general anaesthesia. Effective insertion was confirmed by resistance to further distal movement, manual ventilation, and listening for gas leakage at the mouth. The breathing circuit was connected to the airway channel and airway patency confirmed with manual test ventilation at 20 cm H20 (water) pressure for 3 s. Data was collected in relation to the time for placement, intraoperative performance and postoperative performance of the airway device. Additionally, investigators rated the ease of insertion and adequacy of lung ventilation on a 5-point scale. The median (interquartile range [range]) time taken to insertion of the device was 31 (26-40[14-780]) s with the ability to ventilate after device insertion 100 (95% CI 96.7- 100)%. Secondary endpoints included one or more manoeuvres 60.3 (95% CI 50.6-69.5)% cases requiring to assist insertion; a median ease of insertion score of 4 (2-5[3-5]), and a median adequacy of ventilation score of 5 (5-5[4-5]). However, the first time insertion rate failure was 9.9% (95% CI 5.1-17.0%). There were no episodes of patient harm recorded, particularly desaturation. The LMA Protector appears suitable for clinical use, but an accompanying article discusses our reflections on the ADEPT approach to studying airway devices from a strategic perspective.© 2022. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.