    ObjectiveFlow diverters have revolutionized the endovascular treatment of intracranial aneurysms. Here, the authors present the first large-scale North American multicenter experience using the Flow Redirection Endoluminal Device (FRED) in the treatment of cerebral aneurysms.MethodsConsecutive cerebral aneurysms treated with FRED at 7 North American centers between June 2020 and November 2021 were included. Data collected included patient demographic characteristics, aneurysm characteristics, periprocedural and long-term complications, modified Rankin Scale (mRS) scores, and radiological follow-up.ResultsIn total, 133 aneurysms in 116 patients were treated with 123 FRED deployment procedures and included in this study. One hundred twenty-six aneurysms (94.7%) were unruptured, 117 (88.0%) saccular, and 123 (92.5%) located in anterior circulation. The mean (range) aneurysm maximal width and neck width sizes were 7.2 (1.5-42.5) mm and 4.1 (1.0-15.1) mm, respectively. Successful FRED deployment was achieved in 122 procedures (99.2%). Adjunctive coiling was used in 4 procedures (3.3%). Radiological follow-up was available for 101 aneurysms at a median duration of 7.0 months. At last follow-up, complete occlusion was observed in 55.4% of patients, residual neck in 8.9%, and filling aneurysm in 35.6%; among cases with radiological follow-up duration > 10 months, these values were 21/43 (48.8%), 3/43 (7.0%), and 19/43 (44.2%), respectively. On multivariate regression analysis, age (OR 0.93, p = 0.001) and aneurysm neck size (OR 0.83, p = 0.048) were negatively correlated with odds of complete occlusion at latest follow-up. The retreatment rate was 6/124 (4.8%). The overall complication rate was 31/116 (26.7%). Parent vessel occlusion, covered branch occlusion, and in-stent stenosis were detected in 9/99 (9.1%), 6/63 (9.5%), and 15/99 (15.2%) cases, respectively. The FRED-related, symptomatic, thromboembolic, and hemorrhagic complication rates were 22.4%, 12.9%, 6.9%, and 0.9% respectively. The morbidity rate was 10/116 patients (8.6%). There was 1 death due to massive periprocedural internal carotid artery stroke, and 3.6% of the patients had an mRS score > 2 at the last follow-up (vs 0.9% at baseline).ConclusionsAs the first large-scale North American multicenter FRED experience, this study confirmed the ease of successful FRED deployment but suggested lower efficacy and a higher rate of complications than reported by previous European and South American studies on FRED and other flow-diverting devices. The authors recommend judicious use of this device until future studies can better elucidate the long-term outcomes of FRED treatment.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…