• Spine · Jan 2023

    Dynamic Radiographs are Unreliable to Assess Arthrodesis following Cervical Fusion: A Modeled Radiostereometric Analysis of Cervical Motion.

    • Zachariah W Pinter, Jonathan Skjaerlund, Giorgos D Michalopoulos, Karim R Nathani, Mohamad Bydon, Ahmad Nassr, Arjun S Sebastian, and Brett A Freedman.
    • Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
    • Spine. 2023 Jan 15; 48 (2): 127136127-136.

    Study DesignIn vitro study.ObjectiveThe purpose of the present study was to utilize an idealized cervical spine model to determine whether the parallax effect or changes in the position of the spine relative to the x-ray generator influence intervertebral motion parameters on dynamic cervical spine radiographs.Summary Of Background DataThe utility of flexion-extension radiographs in clinical practice remains in question due to poor reliability of the parameters utilized to measure motion.Materials And MethodsA cervical spine model with tantalum beads inserted into the tip of each spinous process was utilized to measure interspinous process distance (IPD) on plain radiographs. The model was then manipulated to alter the generator angle and generator distance, and the IPD was measured. The impact of individual and combined changes in these parameters on IPD was assessed. Multivariate analysis was performed to identify independent drivers of variability in IPD measurements.ResultsIsolated changes in the generator distance and generator angle and combined changes in these parameters led to significant changes in the measured IPD at each intervertebral level in neutral, flexion, and extension, which, in many instances, exceeded an absolute change of >1 mm or >2 mm. Multivariate analysis revealed that generator distance and generator angle are both independent factors impacting IPD measurements that have an additive effect.ConclusionsIn an idealized cervical spine model, small clinically feasible changes in spine position relative to the x-ray generator produced substantial variability in IPD measurements, with absolute changes that often exceeded established cutoffs for determining the presence of pathologic motion across a fused segment. This study further reinforces that motion assessment on dynamic radiographs is not a reliable method for determining the presence of an arthrodesis unless these sources of variability can be consistently eliminated.Level Of Evidence3.Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.