- Daniel Fell, Elias Diarbakerli, and Paul Gerdhem.
- Department of Reconstructive Orthopaedics, Karolinska University Hospital, 171 76, Solna, Sweden.
- Eur Spine J. 2022 Nov 1; 31 (11): 303630413036-3041.
PurposeThe aim of this study is to evaluate the levels of chromium (Cr), cobalt (Co), and titanium (Ti) after instrumented fusion for scoliosis.MethodsSerum samples were collected at median 2.24 (range 0.1-38.8) years after fusion surgery for scoliosis in 91 individuals, of which 71 had been treated with steel implants and 20 with titanium implants. 91 sex and age-matched non-surgically treated individuals with scoliosis were used as controls. Levels of Cr, Co, and Ti were measured.ResultsIn the 91 surgically treated individuals median levels of Cr were 0.54 µg/l vs 0 µg/l in the 91 controls, p < 0.001. Corresponding results for Co were 0.29 µg/l vs. 0.24 µg/l, p = 0.19, and for Ti were 0 µg/l vs. 0 µg/l, p < 0.001. In the individuals with steel implants and their corresponding controls median Cr levels were 0.63 µg/l vs. 0.00 µg/l, p < 0.001 and Co levels 0.27 µg/l vs. 0.23 µg/l, p = 0.36. No Ti was detected. In the individuals with titanium implants, median Cr levels were 0 µg/l vs. 0 µg/l in their corresponding controls, p = 0.38. Corresponding results for Co was 0.39 µg/l vs. 0.31 µg/l, p = 0.27 and for Ti 4.31 µg/l vs. 0 µg/l, p < 0.001. In the individuals with steel implants a negative correlation between implant time in situ and levels of Cr was found ([Formula: see text] = - 0.52, p < 0.001) but not with Co ([Formula: see text] = - 0.14, p = 0.23). Ti was not detected. In the individuals with titanium implants, there was no correlation between implant time in situ and levels of Cr ([Formula: see text] = 0.36, p = 0.12), Co ([Formula: see text] = - 0.12, p = 0.60) or Ti ([Formula: see text] = 0.22, p = 0.35).ConclusionThe use of stainless steel and titanium implants in spinal fusion surgery is associated with elevated metal ion concentrations several years after surgery.© 2022. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.