• Medicina · Sep 2022

    Atrial Pacing Affects Left Atrial Morphological and Functional Parameters Early after Pacemaker Implantation.

    • Mindaugas Viezelis, Gintare Neverauskaite-Piliponiene, Agne Marcinkeviciene, Eligija Teleisyte, Tomas Kazakevicius, Vytautas Zabiela, Vilius Kviesulaitis, Renaldas Jurkevicius, and Aras Puodziukynas.
    • Department of Cardiology, Lithuanian University of Health Sciences, A. Mickeviciaus Str. 7, LT-44307 Kaunas, Lithuania.
    • Medicina (Kaunas). 2022 Sep 15; 58 (9).

    AbstractBackground and Objectives: Chronic atrial stimulation might impair left atrial (LA) function. We aimed to assess the impact of atrial pacing burden on LA volumetric and functional parameters after implantation of a dual-chamber pacemaker. Materials and Methods: The prospective study included 121 subjects with sinus node disease (SND) or atrioventricular block (AVB) that received a dual-chamber pacemaker. After device implantation, the subjects were divided into three groups: (1) SND with a lower rate (LR) set to 60 bpm and rate response enabled; (2) AVB with an LR set to 60 bpm and no rate response; and (3) AVB with an LR set to 40 bpm and no rate response. Subjects were followed at one and three months. Two subsets of patients with high and low atrial pacing burdens accompanied by low ventricular pacing percentage were analyzed. LA function was evaluated with volumetric and strain parameters from transthoracic echocardiography. Results: The high atrial low ventricular pacing group consisted of 38 subjects, and the low atrial low ventricular group consisted of 22 subjects. When looking at the change in volumetric parameters, we observed a tendency for volumes to increase in both groups; however, only minimal LA volume reached statistical significance at three months in the high atrial pacing group. A trend towards the lowering of an active emptying fraction at one month (p = 0.076) became significant at three months (p = 0.043), and was also only observed in the same group. Moreover, a decrease in the tendency to reach statistical significance at three months for reservoir and contractile strain parameters and stiffness index was only observed in the high atrial pacing group. Meanwhile, in the low atrial pacing burden group, all parameters remained significantly unchanged. Conclusions: The burden of right atrial pacing in patients with preserved left ventricular function negatively influences functional and morphologic LA parameters. Moreover, negative effects take place soon after pacemaker implantation and appear to be sustained.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…