-
Pediatric emergency care · Oct 2022
Comparison of Bedside and Video-Based Capillary Refill Time Assessment in Children.
- Amanda J Nickel, Ryan Brandon Hunter, Shen Jiang, John R Boulet, Jasmine Hanks, Natalie Napolitano, Vinay M Nadkarni, and Akira Nishisaki.
- From the Department of Respiratory Care.
- Pediatr Emerg Care. 2022 Oct 1; 38 (10): 506510506-510.
ObjectivesCapillary refill time (CRT) to assess peripheral perfusion in children with suspected shock may be subject to poor reproducibility. Our objectives were to compare video-based and bedside CRT assessment using a standardized protocol and evaluate interrater and intrarater consistency of video-based CRT (VB-CRT) assessment. We hypothesized that measurement errors associated with raters would be low for both standardized bedside CRT and VB-CRT as well as VB-CRT across raters.MethodsNinety-nine children (aged 1-12 y) had 5 consecutive bedside CRT assessments by an experienced critical care clinician following a standardized protocol. Each CRT assessment was video recorded on a black background. Thirty video clips (10 with bedside CRT < 1 s, 10 with CRT 1-2 s, and 10 with CRT > 2 s) were randomly selected and presented to 10 clinicians twice in randomized order. They were instructed to push a button when they visualized release of compression and completion of a capillary refill. The correlation and absolute difference between bedside and VB-CRT were assessed. Consistency across raters and within each rater was analyzed using the intraclass correlation coefficient (ICC). A Generalizability study was performed to evaluate sources of variation.ResultsWe found moderate agreement between bedside and VB-CRT observations (r = 0.65; P < 0.001). The VB-CRT values were shorter by 0.17 s (95% confidence interval, 0.09-0.25; P < 0.001) on average compared with bedside CRT. There was moderate agreement in VB-CRT across raters (ICC = 0.61). Consistency of repeated VB-CRT within each rater was moderate (ICC = 0.71). Generalizability study revealed the source of largest variance was from individual patient video clips (57%), followed by interaction of the VB-CRT reviewer and patient video clip (10.7%).ConclusionsBedside and VB-CRT observations showed moderate consistency. Using video-based assessment, moderate consistency was also observed across raters and within each rater. Further investigation to standardize and automate CRT measurement is warranted.Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.