• Pediatric emergency care · Oct 2022

    Comparison of Bedside and Video-Based Capillary Refill Time Assessment in Children.

    • Amanda J Nickel, Ryan Brandon Hunter, Shen Jiang, John R Boulet, Jasmine Hanks, Natalie Napolitano, Vinay M Nadkarni, and Akira Nishisaki.
    • From the Department of Respiratory Care.
    • Pediatr Emerg Care. 2022 Oct 1; 38 (10): 506510506-510.

    ObjectivesCapillary refill time (CRT) to assess peripheral perfusion in children with suspected shock may be subject to poor reproducibility. Our objectives were to compare video-based and bedside CRT assessment using a standardized protocol and evaluate interrater and intrarater consistency of video-based CRT (VB-CRT) assessment. We hypothesized that measurement errors associated with raters would be low for both standardized bedside CRT and VB-CRT as well as VB-CRT across raters.MethodsNinety-nine children (aged 1-12 y) had 5 consecutive bedside CRT assessments by an experienced critical care clinician following a standardized protocol. Each CRT assessment was video recorded on a black background. Thirty video clips (10 with bedside CRT < 1 s, 10 with CRT 1-2 s, and 10 with CRT > 2 s) were randomly selected and presented to 10 clinicians twice in randomized order. They were instructed to push a button when they visualized release of compression and completion of a capillary refill. The correlation and absolute difference between bedside and VB-CRT were assessed. Consistency across raters and within each rater was analyzed using the intraclass correlation coefficient (ICC). A Generalizability study was performed to evaluate sources of variation.ResultsWe found moderate agreement between bedside and VB-CRT observations (r = 0.65; P < 0.001). The VB-CRT values were shorter by 0.17 s (95% confidence interval, 0.09-0.25; P < 0.001) on average compared with bedside CRT. There was moderate agreement in VB-CRT across raters (ICC = 0.61). Consistency of repeated VB-CRT within each rater was moderate (ICC = 0.71). Generalizability study revealed the source of largest variance was from individual patient video clips (57%), followed by interaction of the VB-CRT reviewer and patient video clip (10.7%).ConclusionsBedside and VB-CRT observations showed moderate consistency. Using video-based assessment, moderate consistency was also observed across raters and within each rater. Further investigation to standardize and automate CRT measurement is warranted.Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.