• J. Neurol. Neurosurg. Psychiatr. · Mar 2023

    Review Meta Analysis

    STN-DBS electrode placement accuracy and motor improvement in Parkinson's disease: systematic review and individual patient meta-analysis.

    • Naomi I Kremer, Teus van Laar, Stèfan F Lange, Sijmen Statius Muller, Sacha la Bastide-van Gemert, Dl Marinus Oterdoom, Gea Drost, and van DijkJ Marc CJMC0000-0002-0814-5680Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands..
    • Neurosurgery, University of Groningen, University Medical Centre Groningen, Groningen, The Netherlands.
    • J. Neurol. Neurosurg. Psychiatr. 2023 Mar 1; 94 (3): 236244236-244.

    AbstractDeep brain stimulation (DBS) of the subthalamic nucleus (STN) is an effective neurosurgical treatment for Parkinson's disease. Surgical accuracy is a critical determinant to achieve an adequate DBS effect on motor performance. A two-millimetre surgical accuracy is commonly accepted, but scientific evidence is lacking. A systematic review and meta-analysis of study-level and individual patient data (IPD) was performed by a comprehensive search in MEDLINE, EMBASE and Cochrane Library. Primary outcome measures were (1) radial error between the implanted electrode and target; (2) DBS motor improvement on the Unified Parkinson's Disease Rating Scale part III (motor examination). On a study level, meta-regression analysis was performed. Also, publication bias was assessed. For IPD meta-analysis, a linear mixed effects model was used. Forty studies (1391 patients) were included, reporting radial errors of 0.45-1.86 mm. Errors within this range did not significantly influence the DBS effect on motor improvement. Additional IPD analysis (206 patients) revealed that a mean radial error of 1.13±0.75 mm did not significantly change the extent of DBS motor improvement. Our meta-analysis showed a huge publication bias on accuracy data in DBS. Therefore, the current literature does not provide an unequivocal upper threshold for acceptable accuracy of STN-DBS surgery. Based on the current literature, DBS-electrodes placed within a 2 mm range of the intended target do not have to be repositioned to enhance motor improvement after STN-DBS for Parkinson's disease. However, an indisputable upper cut-off value for surgical accuracy remains to be established. PROSPERO registration number is CRD42018089539.© Author(s) (or their employer(s)) 2023. No commercial re-use. See rights and permissions. Published by BMJ.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…