• Respiratory care · Jan 2023

    Variability in Cardiopulmonary Exercise Testing Biologic Controls.

    • Thomas W DeCato, Hans C Haverkamp, Thomas Gooding, Dave S Collingridge, and Matthew J Hegewald.
    • Division of Respiratory and Critical Care Physiology and Medicine and The Lundquist Institute for Biomedical Innovation at Harbor-UCLA Medical Center, Torrance, California; and Department of Medical Education and Clinical Sciences, Elson S. Floyd College of Medicine, Washington State University, Spokane, Washington. tdecato@ucla.edu.
    • Respir Care. 2023 Jan 1; 68 (1): 384338-43.

    BackgroundCardiopulmonary exercise testing is an increasingly common test and is considered the accepted standard for assessing exercise capacity. Quantifying variability is important to assess the instrument for quality control purposes. Though guidelines recommend biologic control testing, there are minimal data on how to do it. We sought to describe variability for oxygen consumption (V̇O2 ), carbon dioxide production (V̇CO2 ), and minute ventilation (V̇E) at various work rates under steady-state conditions in multiple subjects over a 1-y period to provide a practical approach to assess and perform biologic control testing.MethodsWe performed a single-center, prospective study with 4 healthy subjects, 2 men and 2 women. Subjects performed constant work rate exercise tests for 6 min each at 25-100 W intervals on a computer-controlled cycle ergometer. Data were averaged over the last 120 s at each work rate to reflect stepwise steady-state conditions. Descriptive statistics, including the mean, median, range, SD, and coefficient of variation (CoV) are reported for each individual across the 4 work rates and all repetitions. As these data were normative, z-scores were utilized, and a value greater than ± 1.96 z-scores was used to define significant test variability.ResultsSubjects performed 16-39 biocontrol studies over 1-y. The mean CoV for all subjects in V̇O2 was 6.59%, V̇CO2 was 6.41%, and V̇E was 6.32%. The ± 1.96 z-scores corresponded to a 9.4-18.1% change in V̇O2 , a 9.6-18.1% change in V̇CO2 , and a 9-21.5% change in V̇E across the 4 workloads.ConclusionsWe report long-term variability for steady-state measurement of V̇O2 , V̇CO2 , and V̇E obtained during biocontrol testing. Utilizing ± 1.96 z-scores allows one to determine if a result exceeds expected variability, which may warrant investigation of the instrument.Copyright © 2023 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…