• Int J Clin Monit Comput · Jan 1995

    Comparative Study

    Double burst monitoring during surgical degrees of neuromuscular blockade: a comparison with train-of-four.

    • H Kirkegaard-Nielsen, H S Helbo-Hansen, P Lindholm, I K Severinsen, and K Bülow.
    • Department of Anaesthesia and Intensive Care, Odense University Hospital, Denmark.
    • Int J Clin Monit Comput. 1995 Jan 1;12(4):191-6.

    UnlabelledWith double burst stimulation (DBS) it is possible to monitor more profound degrees of neuromuscular blockade than with train-of-four stimulation (TOF). It may therefore be indicated to change between DBS and TOF stimulation during moderate to profound degrees of neuromuscular blockade. Consequently, the aim of the study was to evaluate and compare the twitch height of the first twitch (D1) in DBS and the twitch height of the first twitch (T1) in TOF stimulation during moderate to profound degrees of neuromuscular blockade. Thirty-three patients scheduled for gynaecological laparotomy under general anaesthesia were studied. Mechanomyography was used for neuromuscular monitoring. The T1 twitch height before atracurium was administered served as the control twitch height (T1 control). T1 control was considered as 100%. A constant degree of neuromuscular blockade was maintained at a T1 twitch height at a point between 4 and 11% of T1 control, using a continuous infusion of atracurium. Sequences of 16 DBS and 16 TOF stimulations were given. Two different DBS patterns were examined: DBS3,350/50, (3 stimuli at 50 Hz followed 0.75 sec later by 3 stimuli at 50 Hz), and DBS3,380/40, (3 stimuli at 80 Hz followed 0.75 sec later by 3 stimuli at 40 Hz). The data were analysed by the method described by Bland and Altman. The D1 repeatability coefficients of 1.72% for DBS3,350/50 and 1.20% for DBS3,380/40 were significantly greater than the repeatability coefficient of 1.02% for T1 (p <0.05). The D1 bias of 16.7% for DBS3,350/50 was significantly less than the D1 bias of 25.7% for DBS3,380/40 (p <0.05). The limits of agreement between D1 and T1 were 0.1 to 33.3% for DBS3,350/50 and 2.9 to 48.5% for DBS3,380/40.In ConclusionThe repeatability of responses to DBS and TOF stimulations during moderate to profound degrees of neuromuscular blockade where only one twitch is consistently present is satisfactory. The responses to DBS were greater than responses to TOF as indicated by a positive bias of DBS. The limits of agreement between DBS and TOF responses were so wide that they cannot be used interchangeably.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…