    Validation of a miniaturized handheld arterial pressure monitor for guiding full and partial REBOA use during resuscitation.

    • Derek A Benham, Matthew J Carr, Lyndsey Wessels, Joseph J Lee, Richard Y Calvo, Andrew Schrader, Torbjorg Holtestaul, Daniel Lammers, Ian Jones, Jeffrey Connor, Jessica Weiss, Matthew J Eckert, Michael Krzyzaniak, and Matthew J Martin.
    • Department of Surgery, Naval Medical Center San Diego, San Diego, CA, USA.
    • Eur J Trauma Emerg Surg. 2023 Apr 1; 49 (2): 795801795-801.

    PurposeResuscitative endovascular balloon occlusion of the aorta (REBOA) is a well-validated method for the control of noncompressible truncal hemorrhage. In lower resource or battlefield settings, the need for arterial line setup and monitoring is problematic and potentially prohibitive. We sought to evaluate the accuracy and precision of a miniaturized portable device (Centurion COMPASS®) versus standard arterial pressure monitoring using standard ER-REBOA and partial REBOA (pREBOA) as a high-fidelity and space-/time-conserving alternative.MethodsA total of 40 swine underwent a four-phase validation/precision study (each phase using five ER-REBOAs and five pREBOAs). Phases I/II evaluated accuracy with full and pREBOA in uninjured animals. Phases III/IV duplicated the previous phases but in a severe hemorrhagic shock model. Carotid and femoral pressures were monitored with both intra-arterial pressure systems and the COMPASS® device. The vascular flow was measured by aortic flow probes. Correlation and Bland-Altman analysis were performed.ResultsThere was a strong correlation in accuracy testing of proximal and distal COMPASS® devices compared to standard intra-arterial pressure monitoring (r = 0.94, 0.8; p < 0.005) as well as during precision testing (r = 0.98, 0.89 p < 0.005) in the uninjured phases. Similar accuracy and reliability were demonstrated in hemorrhagic shock, with a strong correlation for the proximal and distal COMPASS® devices (r = 0.98, 0.97; p < 0.005), as well as during precision testing (r = 0.99, 0.95; p < 0.005) in both full and pREBOA scenarios. Bland-Altman analysis showed extremely low bias between the COMPASS® and arterial line for both proximal (bias = 1.9) and distal (bias = 0.8) pressure measurements.ConclusionThe COMPASS® provides accurate and precise pressure measurements during standard and partial REBOA in both uninjured and shock conditions. This device may help extend and enhance capability in any low-resource/battlefield settings, or even eliminate the need for standard intra-arterial invasive pressure monitoring and external setup.© 2022. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…