Journal of critical care · Feb 2023
The impact of temporary mechanical circulatory support strategies on thrombocytopenia.
- Henry Dwaah, Nupur Jain, Navin K Kapur, Jamel P Ortoleva, Haval Chweich, Gregory S Couper, and Masashi Kawabori.
- Tufts University School of Medicine, Boston, MA 02111, USA.
- J Crit Care. 2023 Feb 1; 73: 154216154216.
AbstractOne common but not well-understood phenomenon of temporary mechanical circulatory support (MCS) use is thrombocytopenia. This clinical issue increases the risk of bleeding and the need for platelet transfusion. Additionally, heparin-induced thrombocytopenia must be considered as part of the differential diagnosis, which complicates patient management. In what follows, we analyze the degree and relative rate of platelet count drop with various temporary MCS strategies - Impella 5.5; Veno-venous Extracorporeal Membrane Oxygenation (VV ECMO); Veno-arterial ECMO (VA ECMO); Intra-aortic Balloon Pump (IABP) and Centrimag Biventricular Assist Device (BIVAD). A total of 337 cohort was investigated. 77 was included for analysis after strict exclusion criteria were utilized (platelet transfusions, bleeding complications, etc.). Repeated measure mixed effect and linear regression models were used to assess the percent platelet drop on implantation of MCS and recovery after explantation of MCS. A statistically significant mean percent drop occurred in MCS types - VA ECMO(-69.6%, p < 0.001), VV ECMO(-40.9%, p < 0.001), Impella 5.5(-20.9%, p = 0.01) and IABP(-28.3%, p = 0.01), except Centrimag BIVAD(-6.5%, p = 0.61). Platelet recovery to or above baseline occurred in VA ECMO(+107.0%, p = 0.42), Impella 5.5(+117.2%, p = 0.28), IABP(+108.3%, p = 0.37), VV-ECMO(163.3%, p = 0.01*) and Centrimag BIVAD(+100.1%, p = 0.99). These results show that the degree of thrombocytopenia depends on MCS device type and is reversible.Copyright © 2022. Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.