-
- Dong Wang, Lina Cao, and Boya Li.
- MD. Physician, Department of Medical Imaging, Xianyang Cai-Hong Hospital, Xianyang, Shaanxi, China.
- Sao Paulo Med J. 2022 Jan 1; 141 (2): 899789-97.
BackgroundComputer-aided diagnosis in low-dose (≤ 3 mSv) computed tomography (CT) is a potential screening tool for lung nodules, with quality interpretation and less inter-observer variability among readers. Therefore, we aimed to determine the screening potential of CT using a radiation dose that does not exceed 2 mSv.ObjectiveWe aimed to compare the diagnostic parameters of low-dose (< 2 mSv) CT interpretation results using a computer-aided diagnosis system for lung cancer screening with those of a conventional reading system used by radiologists.Design And SettingWe conducted a comparative study of chest CT images for lung cancer screening at three private institutions.MethodsA database of low-dose (< 2 mSv) chest CT images of patients at risk of lung cancer was viewed with the conventional reading system (301 patients and 226 nodules) or computer-aided diagnosis system without any subsequent radiologist review (944 patients and 1,048 nodules).ResultsThe numbers of detected and solid nodules per patient (both P < 0.0001) were higher using the computer-aided diagnosis system than those using the conventional reading system. The nodule size was reported as the maximum size in any plane in the computer-aided diagnosis system. Higher numbers of patients (102 [11%] versus 20 [7%], P = 0.0345) and nodules (154 [15%] versus 17 [8%], P = 0.0035) were diagnosed with cancer using the computer-aided diagnosis system.ConclusionsThe computer-aided diagnosis system facilitates the diagnosis of cancerous nodules, especially solid nodules, in low-dose (< 2 mSv) CT among patients at risk for lung cancer.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.