- Sue Copley, Peter Edward Yassa, Alan Mark Batterham, Eric Buchser, Nagy Mekhail, Rui V Duarte, and Sam Eldabe.
- Department of Pain Medicine, the James Cook University Hospital, Middlesbrough, UK.
- Neuromodulation. 2023 Aug 1; 26 (6): 124012461240-1246.
IntroductionImplantable intrathecal drug delivery (ITDD) devices are used to treat severe pain and spasticity refractory to conventional medical management. Although off-label medications and drug admixtures are commonly used in clinical practice and recommended by international guidelines, manufacturers state that this practice can result in device failure. The impact of off-label drugs and drug combinations on pump accuracy has hitherto never been assessed.Materials And MethodsA multinational, three-center, retrospective review of patient records was undertaken. The inclusion criterion was the presence of an ITDD device implantation in adult patients, with the pump in situ for the expected battery lifespan. Residual drug volumes at each refill, drug mixtures and concentrations, and rate and flow pattern of the pump (simple or flex) were recorded. A normalized flow rate ratio was calculated (actual to theoretical flow rate). The impact of nonapproved drugs, battery life, pump size, and flow program on drug delivery accuracy was assessed.ResultsData from 1402 pump refills were collected (73 patients). The overall mean accuracy ratio was 0.995 (95% CI = 0.986-1.004). The ratio for approved drug status was 0.990 vs 0.997 in nonapproved, with a difference of -0.007 (-0.032 to 0.017). At the tenth centile for remaining battery life (14 months), the ratio was 0.983 vs 1.009 for the 90th centile (69 months), with a difference of -0.026 (-0.038 to -0.014). The ratio for flex administration was 0.982 vs 1.006 for simple, with a difference of -0.024 (-0.040 to -0.008). For pump size of 40 mL, the ratio was 0.975 vs 1.010 for 20 mL, with a difference of -0.035 (-0.063 to -0.008). The 95% prediction interval for individual refill ratios was ±0.15.ConclusionIn a clinical setting, the ITDD pumps retained high levels of accuracy and acceptable precision across their lifespan despite using unapproved drugs or admixtures and under various flow modes and rates.Copyright © 2022 International Neuromodulation Society. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.