-
- Dominique Fabre, Frédéric Kolb, Elie Fadel, Nicolas Leymarie, Sacha Mussot, Thierry Le Chevalier, and Philippe Dartevelle.
- Marie Lannelongue Hospital, Department of Thoracic and Vascular Surgery and Heart-Lung Transplantation, Le Plessis Robinson, France. Electronic address: d.fabre@ccml.fr.
- Presse Med. 2013 Sep 1; 42 (9 Pt 2): e334e341e334-41.
BackgroundDespite numerous attempts, synthetic materials and heterologous tissues failed to replace durably the trachea. Autologous tracheal substitution (ATS) without synthetic material or immunosuppression was investigated to replace extended tracheal defect. We present our experience regards to this innovative challenge.MethodAfter a previous research study, we developed a novel reconstruction technique for extended tracheal defects on animals. Through a single stage operation, a tube from a forearm free fascio-cutaneous flap vascularized by radial vessels is re-anastomosed to cervical vessels. This flap is reinforced by rib cartilages interposed transversally in the subcutaneous tissue. It provides also a reliable ATS. Twelve patients benefits from an extended tracheal resections, 7-12 centimeter (mean 11 cm) long. Indications were eight Primary tracheal Neoplasms (including 5 adenoid cystic carcinoma [ACC] and 3 squamous cell carcinoma [SCC]), three secondary tracheal neoplasms (including 1 thyroid carcinoma and 2 lymphoma) and one post-intubation tracheal destruction after long history of stenting. Daily bronchoscopy and transitory tracheotomy was associated due to absence of mucociliary clearance.ResultsThe research work leads to present the first described animal model for tracheal resection and replacement with an autologous conduit. It was constructed from costal cartilages and a pediculed cervical skin flap. From 2004 to 2012, 12 patients have had ATS with associated resections in four cases. All patients were extubated on the first postoperative days; eight patients are alive at 2 to 94 months (mean=36) postoperatively, with no respiratory distress. The two patients with ATS after resection extended to the carina died due to pulmonary infection. No airway collapse has been detectable, either by endoscopy, dynamic CT scan or spirometry. Two patients still have a tracheotomy because performed too low at the level of the proximal anastomosis. One patient with a chronic severe respiratory insufficiency required recently a distal and short stent.ConclusionATS is actually a good, durable tracheal substitute that can resist respiratory pressure variations because of their transverse rigidity without any immunosuppression. The limits of this technique are probably, chronic respiratory insufficiency and cartilage calcifications. Research to develop a method for lining the neo-trachea with ciliated respiratory epithelium is needed.Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.