• Critical care medicine · Mar 2005

    Intrinsic positive end-expiratory pressure in Acute Respiratory Distress Syndrome (ARDS) Network subjects.

    • Catherine Lee Hough, Richard H Kallet, V Marco Ranieri, Gordon D Rubenfeld, John M Luce, and Leonard D Hudson.
    • Division of Pulmonary and Critical Care Medicine, Department of Medicine at the University of Washington, Seattle, WA, USA.
    • Crit. Care Med. 2005 Mar 1;33(3):527-32.

    ObjectiveWe tested the hypothesis that subjects randomized to the 6 mL/kg predicted body weight tidal volume study group of the National Institutes of Health Acute Respiratory Distress Syndrome (ARDS) Network study had higher levels of intrinsic positive end-expiratory pressure (PEEP) than subjects randomized to the 12 mL/kg predicted body weight tidal volume study group.DesignSecondary analysis of a subgroup from a randomized controlled trial.SettingHospitals located in San Francisco, CA, and Seattle, WA.PatientsEighty-four patients enrolled in the ARDS Network tidal volume trial in San Francisco, CA, and Seattle, WA, with records of measurement of intrinsic PEEP.InterventionsNone.Measurements And Main ResultsIntrinsic PEEP was assessed a median of six times over the first 48 hrs of ARDS Network protocol ventilation in study subjects, with no significant difference in number of measurements between subjects randomized to the tidal volume protocol of 6 mL/kg compared with 12 mL/kg. We found that intrinsic PEEP was higher among subjects randomized to the 6 mL/kg protocol, with a median intrinsic PEEP of 1.3 cm H2O (interquartile range, 0-3.1 cm H2O), compared with a median intrinsic PEEP of 0.5 cm H2O (interquartile range, 0-1.5 cm H2O) among subjects randomized to 12 mL/kg (p = .029). There was no difference in total PEEP between the study groups.ConclusionsIn a subgroup of ARDS Network subjects, intrinsic PEEP was statistically significantly higher in subjects randomized to the 6 mL/kg protocol than those in the 12 mL/kg study group. The amount of intrinsic PEEP was very low in both study groups, and difference of median intrinsic PEEP between the groups was <1 cm H2O. It is unlikely that the difference in intrinsic PEEP between the study groups was clinically important in the ARDS Network study of low tidal volume ventilation.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.