J Clin Monit Comput · Jun 2007
Accuracy of a novel approach to measuring arterial thermodilution cardiac output during intra-aortic counterpulsation.
- Werner Baulig, Philipp Schuett, Oliver Goedje, and Edith R Schmid.
- Division of Cardiac Anaesthesia, Institute of Anaesthesiology, University Hospital of Zurich, Raemistrasse 100, Zurich, 8091, Switzerland. werner.baulig@usz.ch
- J Clin Monit Comput. 2007 Jun 1; 21 (3): 147-53.
ObjectiveTo assess the agreement between a novel approach of arterial and the pulmonary artery bolus thermodilution for measuring cardiac output in critically ill patients during aortic counterpulsation.MethodsEighteen male patients aged 37-80 years, undergoing preoperative insertion of an intra-aortic balloon pump (IABP) and elective coronary artery bypass grafting. A thin 1.3FG thermistor was introduced through the pressure lumen to the tip of an 8FG IABP catheter, and the pump rate was set at 1:1. After arrival in the intensive care unit cardiac output (CO) was measured under haemodynamic steady-state conditions hourly for 8-11 h, and arterial bolus thermodilution (BCO(iabp)) and pulmonary artery bolus thermodilution (BCO(pulm)) were determined after the patients' admission to the intensive care unit.ResultsA total of 198 data pairs were obtained: 177 with aortic counterpulsation and 21 without. During aortic counterpulsation, median CO was 6.8 l/min for BCO(iabp) and 6.1 l/min for BCO(pulm), without aortic counterpulsation; corresponding values were 7.1 l/min for BCO(iabp) and 6.5 l/min for BCO(pulm) with aortic counterpulsation. Mean bias was +0.77 l/min, limits of agreement ( +/- 2 SD) were -1.27/+2.81 l/min, and mean error (2 SD/[(BCO(iabp )+ BCO(pulm))/2] was 31.4%. Without aortic counterpulsation, corresponding values were +0.43 l/min, -1.03/+1.87 l/min, and 22.4%.ConclusionsAgreement between BCO(iabp) and BCO(pulm) was satisfactory for CO values between 2.0 and 10 l/min only without aortic counterpulsation. BCO(iabp) CO measurements during aortic counterpulsation after coronary artery bypass grafting cannot be recommended at the present time.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.