-
The Journal of urology · Feb 2003
Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.
- Jaime Landman, Kurt Kerbl, Jamil Rehman, Cassio Andreoni, Peter A Humphrey, William Collyer, Ephrem Olweny, Chandru Sundaram, and Ralph V Clayman.
- Department of Surgery (Division of Urology), Washington University School of Medicine, St. Louis, Missouri, USA.
- J. Urol. 2003 Feb 1;169(2):697-700.
PurposeWe assessed the usefulness of the LigaSure (Valleylab, Boulder, Colorado) vessel sealing system for vascular control during laparoscopic surgery and compared it with other available hemostatic modalities.Materials And MethodsA total of 31 domestic pigs were divided into 5 groups. In groups 1 and 2 the vessel sealing system was compared with titanium clips and Endo-GIA (United States Surgical, Stamford, Connecticut) staples. In group 3 the vessel sealing system was compared with standard Klepinger (Karl Storz, Culver City, California) bipolar forceps. In group 4 the harmonic scalpel and Trimax (United States Surgical) bipolar forceps were compared. In group 5 in vivo laparoscopic application of the vessel sealing system was evaluated.ResultsThe 5 mm. laparoscopic vessel sealing system sealed arteries up to 6 mm. and veins up to 12 mm. in diameter at supraphysiological bursting pressure. We evaluated 13 arteries with a diameter of 6 mm. or less at a mean bursting pressure of 662 mm. Hg (range 363 to 1,985) and 11 veins with a diameter of 12 mm. or less with a mean bursting pressure of 233 mm. Hg (range 63 to 440). Collateral tissue damage extended 1 to 3 mm. from the application site. Standard bipolar energy with Klepinger and Trimax forceps was less reliable and in some cases vessel sealing could not be accurately assessed before vessel division. Collateral tissue injury was 1 to 6 mm. The harmonic scalpel did not reliably seal vessels larger than 3 mm. but resulted in the least acute collateral tissue injury of 0 to 1 mm.ConclusionsIn the porcine model the LigaSure system is a viable option for laparoscopic management of arteries up to 6 mm. and veins up to 12 mm. in diameter.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.