• J. Thorac. Cardiovasc. Surg. · Mar 2008

    Comparative Study

    The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio.

    • Lognathen Balacumaraswami, Yasir Abu-Omar, Joseph Selvanayagam, David Pigott, and David P Taggart.
    • Department of Cardiothoracic Surgery, John Radcliffe Hospital, Headington, Oxford, United Kingdom.
    • J. Thorac. Cardiovasc. Surg. 2008 Mar 1;135(3):533-9.

    ObjectiveDespite profound differences in the neurohumoral milieu in patients undergoing on-pump and off-pump coronary artery bypass grafting, it is uncertain how this affects graft blood flow.MethodsWe prospectively recorded intraoperative transit-time flow measurements (MediStim BF 2004; MediStim AS, Oslo, Norway) in all internal thoracic artery, radial artery, and long saphenous vein conduits in patients undergoing off-pump and on-pump bypass grafting by a single surgeon. We calculated a flow/pressure ratio as a ratio of mean graft flow to mean arterial pressure for all the conduits just before chest closure.ResultsTransit-time flow measurements were recorded in 266 grafts (203 off-pump; 63 on-pump) in 100 patients (80 off-pump; 20 on-pump). Overall, mean graft flow (milliliters per minute) was higher for all grafts in the on-pump group despite a significantly lower mean arterial pressure compared with the off-pump group (P < .05). Consequently the flow/pressure ratio was greater for all grafts in the on-pump group (internal thoracic artery 0.55 vs 0.35, radial artery 0.61 vs 0.36, long saphenous vein 0.77 vs 0.55). Overall mean graft flow was significantly greater in the long saphenous vein than in the internal thoracic artery (P < .001) and radial artery (P = .001), but there was no significant difference in mean graft flow in internal thoracic artery or radial artery grafts within each group.ConclusionsIn comparison with the off-pump group, the overall mean graft flow and flow/pressure ratio were significantly higher and mean arterial pressure significantly lower for all grafts in the on-pump group. These findings are probably a result of vasodilatation resulting from cardiopulmonary bypass and reactive hyperemia resulting from a period of ischemia. There was no difference in the mean graft flow and flow/pressure ratio of arterial grafts, which were significantly less than for long saphenous vein grafts. In patients with unstable angina and/or hemodynamic instability, in whom rapid and maximum restoration of myocardial perfusion is a priority, potentially lower graft flow in arterial grafts and off-pump surgery should be considered.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,704,841 articles already indexed!

We guarantee your privacy. Your email address will not be shared.