-
Anesthesia and analgesia · Jan 2024
Controlled Clinical TrialEpidemiology of Enterococcus, Staphylococcus aureus, Klebsiella, Acinetobacter, Pseudomonas, and Enterobacter Species Transmission in the Pediatric Anesthesia Work Area Environment With and Without Practitioner Use of a Personalized Body-Worn Alcohol Dispenser.
- Patrick G Fernandez, Franklin Dexter, Jeremiah Brown, Gina Whitney, Matthew D Koff, Scott Cao, and Randy W Loftus.
- From the Division of Pediatric Anesthesiology, Department of Anesthesiology, University of Colorado, Aurora, Colorado.
- Anesth. Analg. 2024 Jan 1; 138 (1): 152160152-160.
BackgroundPersonalized body-worn alcohol dispensers may serve as an important tool for perioperative infection control, but the impact of these devices on the epidemiology of transmission of high-risk Enterococcus , Staphylococcus aureus , Klebsiella, Acinetobacter , Pseudomonas , and Enterobacter (ESKAPE) pathogens is unknown. We aimed to characterize the epidemiology of ESKAPE transmission in the pediatric anesthesia work area environment with and without a personalized body-worn alcohol dispenser.MethodsThis controlled before and after study included 40 pediatric patients enrolled over a 1-year study period. Two groups of operating room cases were compared: (1) operating room cases caring for patients with usual care (December 17, 2019, to August 25, 2020), and (2) operating room cases caring for patients with usual care plus the addition of a personalized, body-worn alcohol hand rub dispenser (September 30, 2020, to December 16, 2020). Operating rooms were randomly selected for observation of ESKAPE transmission in both groups. Device use was tracked via wireless technology and recorded in hourly hand decontamination events.ResultsAnesthesia providers used the alcohol dispenser 3.3 ± 2.1 times per hour. A total of 57 ESKAPE transmission events (29 treatment and 28 control) were identified. The personalized body-worn alcohol dispenser impacted ESKAPE transmission by increasing the contribution of provider hand contamination at case start (21/29 device versus 10/28 usual care; relative risk, [RR] 2.03; 99.17% confidence interval [CI], 1.025-5.27; P = .0066) and decreasing the contribution of environmental contamination at case end (3/29 device versus 12/28 usual care; RR, 0.24; 99.17% CI, 0.022-0.947; P = .0059). ESKAPE pathogen contamination involved 20% (8/40) of patient intravascular devices. There were 85% (34/40) of preoperative patient skin surfaces contaminated with ≥1 (1.78 ± 0.19 [standard deviation {SD}]) ESKAPE pathogens.ConclusionsA personalized body-worn alcohol dispenser can impact the epidemiology of ESKAPE transmission in the pediatric anesthesia work area environment. Improved preoperative patient decolonization and vascular care are indicated to address ESKAPE pathogens among pediatric anesthesia work area reservoirs.Copyright © 2022 International Anesthesia Research Society.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.