• JAMA · Jan 2023

    Use of Recalled Devices in New Device Authorizations Under the US Food and Drug Administration's 510(k) Pathway and Risk of Subsequent Recalls.

    • Kushal T Kadakia, Sanket S Dhruva, César Caraballo, Joseph S Ross, and Harlan M Krumholz.
    • Harvard Medical School, Boston, Massachusetts.
    • JAMA. 2023 Jan 10; 329 (2): 136143136-143.

    ImportanceIn the US, nearly all medical devices progress to market under the 510(k) pathway, which uses previously authorized devices (predicates) to support new authorizations. Current regulations permit manufacturers to use devices subject to a Class I recall-the FDA's most serious designation indicating a high probability of adverse health consequences or death-as predicates for new devices. The consequences for patient safety are not known.ObjectiveTo determine the risk of a future Class I recall associated with using a recalled device as a predicate device in the 510(k) pathway.Design And SettingIn this cross-sectional study, all 510(k) devices subject to Class I recalls from January 2017 through December 2021 (index devices) were identified from the FDA's annual recall listings. Information about predicate devices was extracted from the Devices@FDA database. Devices authorized using index devices as predicates (descendants) were identified using a regulatory intelligence platform. A matched cohort of predicates was constructed to assess the future recall risk from using a predicate device with a Class I recall.Main Outcomes And MeasuresDevices were characterized by their regulatory history and recall history. Risk ratios (RRs) were calculated to compare the risk of future Class I recalls between devices descended from predicates with matched controls.ResultsOf 156 index devices subject to Class I recall from 2017 through 2021, 44 (28.2%) had prior Class I recalls. Predicates were identified for 127 index devices, with 56 (44.1%) using predicates with a Class I recall. One hundred four index devices were also used as predicates to support the authorization of 265 descendant devices, with 50 index devices (48.1%) authorizing a descendant with a Class I recall. Compared with matched controls, devices authorized using predicates with Class I recalls had a higher risk of subsequent Class I recall (6.40 [95% CI, 3.59-11.40]; P<.001).Conclusions And RelevanceMany 510(k) devices subjected to Class I recalls in the US use predicates with a known history of Class I recalls. These devices have substantially higher risk of a subsequent Class I recall. Safeguards for the 510(k) pathway are needed to prevent problematic predicate selection and ensure patient safety.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…