    On the stability of Leksell Vantage stereotactic head frame fixation in Gamma Knife radiosurgery: a study based on cone-beam computed tomography imaging and the High Definition Motion Management system.

    • Mohammed Ghazal, Marcus Fager, Amir Samadi, Michael Gubanski, and Hamza Benmakhlouf.
    • 1Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.
    • J. Neurosurg. 2023 Sep 1; 139 (3): 831839831-839.

    ObjectiveThe authors' objective was to investigate the stability of the newly introduced Vantage stereotactic frame fixation in single-fraction Gamma Knife radiosurgery.MethodsA total of 255 patients were included in this work and treated with the Vantage frame and Leksell Gamma Knife (LGK) Icon equipped with cone-beam computed tomography (CBCT) imaging. After the frame was mounted on the patient's head, a CT scan was acquired. After the patient was positioned on the couch of LGK, CBCT was acquired to verify the target position before treatment delivery. A second CBCT examination was acquired after treatment delivery to assess intrafractional motion. During treatment delivery, the High Definition Motion Management (HDMM) system was enabled to track a marker on the nose tip of the patient as a surrogate of intracranial motion. The stability of the Vantage frame was deconstructed into two parts: 1) motion between CT and the first CBCT prior to treatment delivery (CT-CBCT1), and 2) motion between CBCT procedures during treatment delivery (CBCT1-CBCT2). Transformation between CT and CBCT1 was given by Leksell GammaPlan, whereas transformation between CBCT1 and CBCT2 required mathematical processing of the transformation and coregistration matrices in the source files.ResultsThe average CT-CBCT1 displacement vector was 0.31 mm, with a range as great as 1.09 mm, and 89% and 97% of cases were within 0.5 mm and 0.7 mm, respectively. The CBCT1-CBCT2 displacement vectors averaged at 0.09 mm, with 97% of cases being within 0.2 mm. Spatial shift in the posterior direction was evident, with 94% of cases demonstrating this trend and averaging 0.05 mm. This was attributed to increased pressure on the posterior fixation pins. The HDMM displacement vectors presented larger values with an average of 0.4 mm and a range as great as 1.6 mm, and 98% of cases were within 1.0 mm. The correlation between CBCT1-CBCT2 and HDMM displacements was weak, which was attributed to the high stability of the Vantage frame and consequently small target displacements coupled with the sensitivity of HDMM to face mimics.ConclusionsThis work demonstrated that the Vantage frame possess the same degree of submillimeter stability as the well-established Leksell Coordinate Frame G (G-frame). Displacements between CT and CBCT1 were 3 times higher than between CBCT1 and CBCT2. A suggested HDMM threshold of 1.2 mm ensures a target accuracy within 0.2 mm in Vantage frame treatments.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…