- Hirotoshi Imamura, Nobuyuki Sakai, Chiaki Sakai, Yasuhiro Hasegawa, Akio Hyodo, Koji Iihara, Kazuo Minematsu, Kuniaki Ogasawara, and WICAD Investigators.
- Department of Neurosurgery, National Cerebral and Cardiovascular Center, Suita, Osaka, Japan. Electronic address: i-hiro@zg7.so-net.ne.jp.
- World Neurosurg. 2023 May 1; 173: e48e54e48-e54.
BackgroundThe Wingspan stent system was approved as a rescue device for angioplasty of intracranial atherosclerotic disease (ICAD) in 2012. We conducted the government-recommended Japanese Postmarket Surveillance of Percutaneous Transluminal Angioplasty and Wingspan Stenting for Intracranial Atherosclerotic Disease to monitor Wingspan safety and performance.MethodsIn this open-label, single-arm study at 76 centers in Japan, ICAD subjects were treated with the Wingspan stent between 2014 and 2016. Efficacy end points were successful stent deployment and technical success, defined as stenosis improvement to <50%. Safety end points were ischemic stroke, modified Rankin Scale and National Institutes of Health Stroke Scale scores, adverse events, and mortality. Subjects were considered treated outside of current recommendations if not already receiving antithrombotics or if percutaneous transluminal angioplasty and stenting occurred within 7 days of onset.ResultsThe safety cohort included 305 subjects (mean age: 68.7 + 9.6; 83.3% male). Four subjects were removed due to being out of contract. Therefore, 301 subjects were included (mean age: 68.7 ± 9.7; 84.1% male). Successful stent placement was 96.7%. Technical success was observed in 86.8% of lesions. At 1 year, the rate of restenosis was 15.7%, ischemic stroke was 3.9%, and any stroke was 7.9%. Functionally independent outcome (modified Rankin Scale: 0-2) was 88.9% and mortality 3.0%. Significantly more serious adverse events occurred in subjects treated outside of current recommendations (17.9%) versus subjects treated per current recommendations (8.8%) (P = 0.045).ConclusionsEndovascular treatment using the Wingspan stent for ICAD is safe and effective in the Japanese population.Copyright © 2023 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.