-
- Laura Anneli Ylikauma, Mari Johanna Tuovila, Pasi Petteri Ohtonen, Tiina Maria Erkinaro, Merja Annika Vakkala, Heikki Timo Takala, Janne Henrik Liisanantti, and Timo Ilari Kaakinen.
- Research Group of Surgery, Intensive Care Unit, Anaesthesiology and Intensive Care Medicine, Medical Research Center Oulu, Oulu University Hospital and University of Oulu, PL 21, 90029 OYS, Oulu, Finland. laura.ylikauma@gmail.com.
- BMC Anesthesiol. 2023 Jan 31; 23 (1): 3838.
PurposeVarious malignancies with peritoneal carcinomatosis are treated with cytoreductive surgery and hyperthermic intraperitoneal chemotherapy (HIPEC). The hemodynamic instability resulting from fluid balance alterations during the procedure necessitates reliable hemodynamic monitoring. The aim of the study was to compare the accuracy, precision and trending ability of two less invasive hemodynamic monitors, bioreactance-based Starling SV and pulse power device LiDCOrapid with bolus thermodilution technique with pulmonary artery catheter in the setting of cytoreductive surgery with HIPEC.MethodsThirty-one patients scheduled for cytoreductive surgery were recruited. Twenty-three of them proceeded to HIPEC and were included to the study. Altogether 439 and 430 intraoperative bolus thermodilution injections were compared to simultaneous cardiac index readings obtained with Starling SV and LiDCOrapid, respectively. Bland-Altman method, four-quadrant plots and error grids were used to assess the agreement of the devices.ResultsComparing Starling SV with bolus thermodilution, the bias was acceptable (0.13 l min- 1 m- 2, 95% CI 0.05 to 0.20), but the limits of agreement were wide (- 1.55 to 1.71 l min- 1 m- 2) and the percentage error was high (60.0%). Comparing LiDCOrapid with bolus thermodilution, the bias was acceptable (- 0.26 l min- 1 m- 2, 95% CI - 0.34 to - 0.18), but the limits of agreement were wide (- 1.99 to 1.39 l min- 1 m- 2) and the percentage error was high (57.1%). Trending ability was inadequate with both devices.ConclusionStarling SV and LiDCOrapid were not interchangeable with bolus thermodilution technique limiting their usefulness in the setting of cytoreductive surgery with HIPEC.© 2023. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.