• BMC anesthesiology · Feb 2023

    Randomized Controlled Trial

    Effects of continuous and slow tracheal tube cuff deflation on cough reflex during extubation in noncardiac surgery patients: a randomised clinical trial.

    • Xuan Wang, Guangli Zhu, Jing Tan, Xinyu Cao, and Manlin Duan.
    • Department of Anesthesiology, Benq medical center & Jinling Hospital, Jinling School of Clinical Medicine, Nanjing Medical University, No. 71 Hexi Avenue, Jianye District, Jiangsu Province, 210019, Nan... more jing, People's Republic of China. less
    • BMC Anesthesiol. 2023 Feb 7; 23 (1): 4545.

    BackgroundThe incidence of cough reflex during extubation is 76%. Cough reflex causes severe hemodynamic fluctuations and airway complications. This prospective trial investigated the potential effects of tracheal tube cuff deflation on cough reflex during extubation.MethodsOne hundred and twenty-six patients scheduled for operations within 3 h under general anaesthesia with orotracheal intubation were randomly assigned to one of three groups: control (C), experimental (E) or syringe (S) groups. Patients in group C underwent tracheal tube cuff deflation using a 10-ml syringe in 1 s, patients in group E underwent tracheal tube cuff deflation continuously and slowly in 5 s using a cuff pressure gauge until the pressure was zero and patients in group S underwent tracheal tube cuff deflation using a 10-ml syringe at a speed of 1 ml s-1. The incidence and severity of cough reflexs during extubation and the incidence of postoperative airway complications within 48 h were assessed.ResultsCompared with group C (60.0%), the incidence of cough reflex in group E was 9.8% (p < 0.001) and in group S was 12.5% (p < 0.001). The severity of cough reflex was graded as 2 (1-2) in group C, 1 (1-1) in group E and 1 (1-1) in group S (p < 0.001 for group comparisons). The incidence of hoarseness in group C was 0.0%, in group E was 19.5% and in group S was 5.0% (p < 0.05 for all groups, p = 0.009 between group C and E).ConclusionsCompared with deflating a trachal tube cuff with a 10-ml syringe in 1 s, the use of a 10-ml syringe at a speed of 1 ml s-1 or a cuff pressure guage within 5 s can both reduce the incidence of cough reflex, but deflating with a cuff pressure guage can increase the incidence of postoperative hoarseness.Trial RegistrationChinese Clinical Trial Registry, identifier: ChiCTR2100054089, Date: 08/12/2021.© 2023. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        

    hide…