    BackgroundThe incidence of cough reflex during extubation is 76%. Cough reflex causes severe hemodynamic fluctuations and airway complications. This prospective trial investigated the potential effects of tracheal tube cuff deflation on cough reflex during extubation.MethodsOne hundred and twenty-six patients scheduled for operations within 3 h under general anaesthesia with orotracheal intubation were randomly assigned to one of three groups: control (C), experimental (E) or syringe (S) groups. Patients in group C underwent tracheal tube cuff deflation using a 10-ml syringe in 1 s, patients in group E underwent tracheal tube cuff deflation continuously and slowly in 5 s using a cuff pressure gauge until the pressure was zero and patients in group S underwent tracheal tube cuff deflation using a 10-ml syringe at a speed of 1 ml s-1. The incidence and severity of cough reflexs during extubation and the incidence of postoperative airway complications within 48 h were assessed.ResultsCompared with group C (60.0%), the incidence of cough reflex in group E was 9.8% (p < 0.001) and in group S was 12.5% (p < 0.001). The severity of cough reflex was graded as 2 (1-2) in group C, 1 (1-1) in group E and 1 (1-1) in group S (p < 0.001 for group comparisons). The incidence of hoarseness in group C was 0.0%, in group E was 19.5% and in group S was 5.0% (p < 0.05 for all groups, p = 0.009 between group C and E).ConclusionsCompared with deflating a trachal tube cuff with a 10-ml syringe in 1 s, the use of a 10-ml syringe at a speed of 1 ml s-1 or a cuff pressure guage within 5 s can both reduce the incidence of cough reflex, but deflating with a cuff pressure guage can increase the incidence of postoperative hoarseness.Trial RegistrationChinese Clinical Trial Registry, identifier: ChiCTR2100054089, Date: 08/12/2021.© 2023. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…