• Can J Anaesth · Oct 1998

    Comparative Study

    Transoesophageal echocardiography during scoliosis repair: comparison with CVP monitoring.

    • D E Soliman, A D Maslow, P M Bokesch, M Strafford, L Karlin, J Rhodes, and G R Marx.
    • Department of Anaesthesia, New England Medical Center, Boston, MA, USA.
    • Can J Anaesth. 1998 Oct 1;45(10):925-32.

    PurposeAccurate haemodynamic assessment during surgical repair of scoliosis is crucial to the care of the patient. The purpose of this study was to compare transoesophageal echocardiography (TEE) with central venous pressure monitoring in patients with spinal deformities requiring surgery in the prone position.MethodsTwelve paediatric patients undergoing corrective spinal surgery for scoliosis/kyphosis in the prone position were studied. Monitoring included TEE, intra-arterial and central venous pressure monitoring (CVP). Haemodynamic assessment was performed prior to and immediately after positioning the patient prone on the Relton-Hall table. Data consisted of mean arterial blood pressure (mBP), heart rate (HR), CVP, left ventricular end-systolic and end-diastolic diameters (LVESD and LVEDD respectively) and fractional shortening (FS). Right ventricular (RV) function and tricuspid regurgitation (TR) were assessed qualitatively. Analysis was performed using descriptive statistics, Student's t test, sign rank, and correlation analysis.ResultsThere was an increase in CVP (8.7 mmHg to 17.7 mmHg; P < .01), and decreases in LVEDD (37.1 mm to 33.2 mm; P < .05), and mean blood pressure (75.0 mmHg to 65.7 mmHg; P < .05) when patients were placed in the prone position. Fractional shortening, LVESD, and HR did not change from the supine to the prone position. Right ventricular systolic function and tricuspid regurgitation were unchanged.ConclusionThese data indicate that the CVP is a misleading monitor of cardiac volume in patients with kyphosis/scoliosis in the prone position. This is consistent with previous studies. In this clinical situation, TEE may be a more useful monitoring tool to assess on-line ventricular size and function.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…