• Medicine · Feb 2023

    Meta Analysis

    Hemodynamic response related to the Airway Scope versus the Macintosh laryngoscope: A systematic review and meta-analysis with trial sequential analysis.

    • Takumi Nagumo, Hiroshi Hoshijima, Koichi Maruyama, Takahiro Mihara, Tsutomu Mieda, Aiji Sato Boku, Toshiya Shiga, and Hiroshi Nagasaka.
    • Department of Anesthesiology, Saitama Medical University Hospital, Moroyama, Saitama, Japan.
    • Medicine (Baltimore). 2023 Feb 22; 102 (8): e33047e33047.

    BackgroundIt is important to reduce the hemodynamic response during tracheal intubation. We performed a systematic review and meta-analysis of the Airway Scope and Macintosh laryngoscope to determine whether they reduce the hemodynamic responses of heart rate (HR) and mean blood pressure (MBP) after tracheal intubation under general anesthesia.MethodsWe performed a comprehensive literature search of electronic databases for clinical trials comparing hemodynamic response to tracheal intubation. The primary aim of our meta-analyst is to determine if the Airway Scope reduces hemodynamic responses (HR and mean MBP) 60 seconds after tracheal intubation compared to the Macintosh laryngoscope. We expressed pooled differences in hemodynamic responses between the 2 devices as weighted mean differences with 95% confidence intervals. We conducted trial sequential analysis. Secondarily, we investigated the ability of the Airway Scope and Macintosh laryngoscope to reduce hemodynamic responses at 120 seconds, 180 seconds, and 300 seconds after tracheal intubation.ResultsWe identified clinical trials comparing hemodynamic response via a comprehensive literature search. Of 185 articles found in the search, we selected 8. In comparison to the Macintosh laryngoscope, the Airway Scope significantly reduced HR and MBP at 60 seconds after tracheal intubation (HR; weighted mean difference = -7.29; 95% confidence interval, -10.9 to -3.62; P < .0001; I2 = 57%, MBP; weighted mean difference = -11.5; 95% confidence interval, -20.4 to -2.65; P = .01; I2 = 91%). At the secondary outcome, the Airway Scope significantly reduced the fluctuation of HR after 120 seconds and 180 seconds of tracheal intubation. However, the Airway Scope did not significantly reduce MBP 120 seconds, 180 seconds, and 300 seconds after tracheal intubation. Trial sequential analysis suggested that the total sample size reached the required information size for heart rate.ConclusionsOur finding suggested that the Airway Scope attenuated hemodynamic responses at 60 seconds after tracheal intubation in comparison with that of the Macintosh laryngoscope. However, the MBP sample size is small and further research is needed.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…