• Diabet. Med. · Jan 2012

    Are arterial and venous samples clinically equivalent for the estimation of pH, serum bicarbonate and potassium concentration in critically ill patients?

    • W G Herrington, H J Nye, M S Hammersley, and P J Watkinson.
    • Department of Acute General Medicine, The John Radcliffe Hospital Kadoorie Centre for Critical Care Research and Education, The John Radcliffe Hospital, Oxford, UK.
    • Diabet. Med. 2012 Jan 1;29(1):32-5.

    AimsTo assess the comparability of venous and arterial samples for pH, bicarbonate and potassium measurements in critically ill patients.MethodsSimultaneous arterial and venous samples from 206 critically ill patients were analysed in duplicate. Coefficients of variation and 95% limits of agreement were calculated for arterial and venous samples. Bland-Altman plots were constructed to assess agreement between sampling sites.ResultsThe median (range) of arterial pH, bicarbonate concentrations, potassium concentrations and glucose concentrations were 7.40 (7.01-7.56), 25 (9-41) mmol/l, 4.2 (3.1-6.8) mmol/l and 7.4 (3.0-13.5) mmol/l, respectively. Coefficients of variation for arterial and venous pH were both 0.1%, with bias (95% limits of agreement) of -0.01 (-0.03 to 0.01) for arterial and -0.01 (-0.02 to 0.01) for venous samples. The bias (95% limits of agreement) between arterial and venous samples was 0.03 (-0.02 to 0.08). Coefficients of variation for arterial and venous bicarbonate results were 0.8 and 0.7%, respectively, with bias (95% limits of agreement) of 0 (-0.5 to 0.5) mmol/l for both sample types. The bias (95% limits of agreement) between venous and arterial samples was 0 (-1.3 to 1.3) mmol/l. Coefficients of variation for arterial and venous potassium samples were 0.8 and 1.1%, respectively, with bias (95% limits of agreement) of 0 (-0.1 to 0.1) for both sample types. The bias (95% limits of agreement) between venous and arterial samples was 0.1 (-0.4 to 0.6) mmol/l.ConclusionsA venous blood sample, analysed on a blood gas machine, is sufficiently reliable to assess pH, bicarbonate and potassium concentrations in critically ill patients, suggesting that venous sampling alone is appropriate in the management of diabetic ketoacidosis.© 2011 The Authors. Diabetic Medicine © 2011 Diabetes UK.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…