• Prehosp Emerg Care · Jan 2024

    LUCAS Device Use Associated with Prolonged Pauses During Application and Long Chest Compression Intervals.

    • Sean Morgan, GrayJ JordanJJDepartment of Emergency Medicine, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire., Woodrow Sams, Kevin Uhl, Michael Gundrum, and Jason McMullan.
    • Department of Emergency Medicine, University of Colorado School of Medicine, Aurora, Colorado.
    • Prehosp Emerg Care. 2024 Jan 1; 28 (1): 114117114-117.

    BackgroundTenets of high-quality out-of-hospital cardiac arrest (OHCA) resuscitation include early recognition and treatment of shockable rhythms, and minimizing interruptions in compressions. Little is known about how use of a mechanical compression device affects these elements. We hypothesize that use of such a device is associated with prolonged pauses in compressions to apply the device, and long compression intervals overall.MethodsWe systematically abstracted CPR metrics from 4 months of adult non-traumatic OHCA cases, each of which had at least 10 minutes of resuscitation, used a LUCAS device, and had a valid monitor file attached to the patient care report. Our primary outcomes of interest were the duration of each pause in compressions and the duration of compressions between pauses, stratified by whether or not the LUCAS device was used/applied during the segment. Each pause was further evaluated for a possible associated procedure based on pre-defined criteria. Descriptive statistics, chi-square, and Kruskal-Wallis tests were used as appropriate.ResultsFifty-eight cases were included, median age 62.5 years (IQR 49.3-70.8), 47% female, 66% nonwhite. Overall, 633 compression-pause segments were analyzed (517 with and 116 without LUCAS applied). Spacing of pauses was significantly longer with the LUCAS than without [median (IQR) 133 (82-213) seconds vs. 38 (18-62) seconds, p < 0.05]. When using a LUCAS, compressions were continuous for at least 3 min in 166/517 segments, at least 4 min in 89/517 segments, and at least 5 min in 56/517 segments. Without a LUCAS, compressions were longer than 3 min in 7/116 segments. Pauses exceeded 10 s more frequently with LUCAS application (32/38) than airway management or defibrillation (27/80, p < 0.05). Peri-LUCAS pauses exceeded 30 s in 6/38 cases.ConclusionLUCAS use was associated with long compression intervals without identifiable pauses to assess for pulse or cardiac rhythm, and device application was associated with longer pauses than airway management or defibrillation. The clinical significance and effect on patient outcomes remain uncertain and require further study.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…