-
Ulus Travma Acil Cer · Mar 2023
The effectiveness of fixation of hydroxyapatite-coated helical blade in preventing of the cut-out observed in treatment with proximal femoral nail of fractures of the femur intertrochanteric in elderly.
- Haci Bayram Tosun, Abuzer Uludağ, Sancar Serbest, Necati Çiçek, and Sukru Demir.
- Department of Orthopaedics and Traumatology, SBÜ Elazığ Fethi Sekin Şehir SUAM, Elazığ-Türkiye.
- Ulus Travma Acil Cer. 2023 Mar 1; 29 (3): 379388379-388.
BackgroundThis study aimed to retrospectively evaluate the effectiveness of hydroxyapatite-coated (HA-coated) implants and other caput-collum implants in preventing cut-out observed in treatment with proximal femoral nail (PFN) of intertrochanteric femur fractures in elderly patients.MethodsA total of 98 consecutive patients (56 males and 42 females; mean age: 79.42 (61-115) years) treated with three differ-ent PFNs for intertrochanteric femoral fractures were retrospectively examined. The mean of the follow-up period was 7.87 (4-48) months. It was used a threaded lag screw in 40 patients, an HA-coated helical blade in 28 patients and a non-coated helical blade in 30 patients for PFN. The reduction quality, fracture type, and radiological outcomes among all groups were evaluated.ResultsUnstable type was seen in 50 (52.1%) patients according to AO Foundation/Orthopedic Trauma Association fracture classi-fication. An acceptable-good reduction quality was seen in 87 (88.8%) of all patients. The average of tip-apex distance (TAD) value was 27.61 mm, calcar-referenced TAD (CalTAD) value was 28.72 mm, caput-collum diaphyseal angle was 128,° Parker's anteroposterior ratio was 46.36%, and Parker's lateral ratio was 46.82%. The best suitable implant position was observed in 49 (50%) patients. Cut-out was observed in 7 (7.14%) patients, and secondary varus displacement of more than 10° was observed in 12 (12.24%) patients. Correlation analysis and multivariate logistic regression analysis showed a significant difference between HA-coated and other implants in cut-out. Furthermore, implant type was the strongest predictive factor for cut-out complications in the multivariate logistic regression analysis.ConclusionHA-coated implants may reduce the long-term cut-out risk due to increased osteointegration and bone ingrowth in elderly patients with intertrochanteric femoral fractures with poor bone quality. However, this alone is not enough; a suitable screw position, optimal TAD values, and excellent reduction quality are other important factors.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.