• Journal of anesthesia · Jun 2023

    Observational Study

    Accuracy of a noninvasive estimated continuous cardiac output measurement under different respiratory conditions: a prospective observational study.

    • Masashi Takakura, Tasuku Fujii, Tomoya Taniguchi, Shogo Suzuki, and Kimitoshi Nishiwaki.
    • Department of Anesthesiology, Nagoya University Hospital, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.
    • J Anesth. 2023 Jun 1; 37 (3): 394400394-400.

    PurposeThe estimated continuous cardiac output (esCCO) system was recently developed as a noninvasive hemodynamic monitoring alternative to the thermodilution cardiac output (TDCO). However, the accuracy of continuous cardiac output measurements by the esCCO system compared to TDCO under different respiratory conditions remains unclear. This prospective study aimed to assess the clinical accuracy of the esCCO system by continuously measuring the esCCO and TDCO.MethodsForty patients who had undergone cardiac surgery with a pulmonary artery catheter were enrolled. We compared the esCCO with TDCO from mechanical ventilation to spontaneous respiration through extubation. Patients undergoing cardiac pacing during esCCO measurement, those receiving treatment with an intra-aortic balloon pump, and those with measurement errors or missing data were excluded. In total, 23 patients were included. Agreement between the esCCO and TDCO measurements was evaluated using Bland-Altman analysis with a 20 min moving average of the esCCO.ResultsThe paired esCCO and TDCO measurements (939 points before extubation and 1112 points after extubation) were compared. The respective bias and standard deviation (SD) values were 0.13 L/min and 0.60 L/min before extubation, and - 0.48 L/min and 0.78 L/min after extubation. There was a significant difference in bias before and after extubation (P < 0.001); the SD before and after extubation was not significant (P = 0.315). The percentage errors were 25.1% before extubation and 29.6% after extubation, which is the criterion for acceptance of a new technique.ConclusionThe accuracy of the esCCO system is clinically acceptable to that of TDCO under mechanical ventilation and spontaneous respiration.© 2023. The Author(s) under exclusive licence to Japanese Society of Anesthesiologists.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…